background image

When removing air filter, do not 
touch metal parts of the unit.

Doing so may cause an injury.

.

Cleaning unit when power is ON 
may cause fire and electric shock
and may cause an injury. 

Operation with windows open may
cause moisture to enter the room.

 

 

 

 

Stop operation and close the
window in severe storms or 
hurricanes.

Do not clean with water.

Water may enter the unit and 
degrade the insulation causing an 
electric shock.

This could injure the pet or plant.

Failure to do so may cause electric

shock and damage.

Do not put a pet or house plant 
where it will be exposed to 
direct air flow.

Hold the plug by the head of the
power plug when taking it out.

Ensure proper ventilation 
especially in rooms with a stove 
or other appliances.

Failure to do so may result in an
oxygen shortage.

This unit is NOT intended to 

preserve precision devices, food, 

pets, plants, and art objects. It may

cause deterioration of quality, etc.

Leaving power on may cause unit 
failure or fire.

Use only as intended.

If unit will not be used for a long
period of time, turn OFF main 
power switch.

 

 

 

 

 

 

If water enters the unit, turn the unit off at the power 
outlet and switch off the circuit breaker. Isolate supply
by taking the power-plug out and contact a qualified 
serviced technician. 

Obstacles may cause appliance 
failure or accident.

Cleaners or detergents may change 
the color or scratch the surface of
the unit.

Do not place obstacles around 
air-inlets or inside of air-outlet.

Use only a soft cloth to clean
the unit.

Prolonged exposure to outdoor
elements may cause damage to
installation bracket causing unit to 
fall.

There is danger of electric shock.

Periodically check installation
bracket for damage.

.

Operation without secured filters
may cause failure. A dirty filter 
can cause the unit to not run
efficiently.

Water from unit contains 
contaminants and could cause 
illness.

Always insert the filters securely. 
Clean filter AT LEAST once 
every two weeks.

NEVER drink water drained from
air conditioner.

Unit and Circuit breaker/fuse
must be switched OFF when
cleaning. 

Do not place heavy objects on the power cord 
and always ensure that the cord is not 
compressed.

Use caution when unpacking 
and installing. 

Sharp edges could cause injury.

!

!

!

!

!

!

!

!

!

!

!

There is danger of fire or electric shock.

!

CAUTION

3

Содержание 2PATWH12000

Страница 1: ......

Страница 2: ...ry The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air conditioner Disabled persons may r...

Страница 3: ...nd burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may cause fire and electric...

Страница 4: ...ime turn OFF main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified ser...

Страница 5: ...zed repairman Operation of Current Device 1 Plug in the air conditioner 2 The power supply cord will have TWO buttons on the plug head Press the TEST button The RESET button will click as it pops out...

Страница 6: ...earance of the control panel on the air conditioner purchased may be slightly different NORMAL SOUNDS AIR CONDITIONER FEATURES Before you begin thoroughly familiarize yourself with the control panel a...

Страница 7: ...fan speed mode is shifted On Dry mode the fan speed is controlled at low automatically For some models with heating capabilities the fan speed cannot be adjusted under Heat mode NOTE The unit will aut...

Страница 8: ...y and Auto only Auto Cooling and Auto Fan modes NOTE MODE button To operate on Auto feature To operate on Fan only not available on all models Use this function only when cooling is not desired such a...

Страница 9: ...Auto Stop program is initiated Turning the unit on or off at any time or adjusting the timer setting to 0 0 will cancel the Auto Start Stop function This feature is a reminder to clean the Air Filter...

Страница 10: ...ntal louvers until the desired up down direction is obtained Move the center handles from side to side until the desired left right direction is obtained Air Direction 4 way Read these instructions co...

Страница 11: ...7 16 3 4 16 3 4 or 19 3 4 Sears Kenmore Carrier 51S Series 25 3 4 16 7 8 18 5 8 Fedders Emerson 26 3 4 15 3 4 15 Friedrich 27 16 3 4 16 3 4 Brand Width Height Depth Note Note Please verify dimensions...

Страница 12: ...new unit remove the screw from the left side front 7 Assemble and install the Trim Frame see instructions IMPORTANT The unit s increased performance characteristics result from having two rear air in...

Страница 13: ...ch 2 4 x 3 x1 centering support blocks one on each side wall Place in center of side wall with the tapered end facing the opening 6 Gently slide unit into sleeve 7 Before sliding all the way back remo...

Страница 14: ...t 5 Attach 1 1 x 3 8 x 25 long seal in the center at the top of the sleeve Remove the backing paper and press into position 6 Attach 2 1 x 3 8 x 14 long seals to the left and right sides of the sleeve...

Страница 15: ...at the top of the sleeve Remove backing paper and press into position 6 Attach 2 1 x 3 8 x 14 seals to the left and right sides of the sleeve 7 Cut 2 1 x 3 8 x 25 long seals to 14 long and attach to...

Страница 16: ...of the sleeve 6 Cut 2 1 x 3 8 x 25 long seals to 14 long and attach to the vertical sections of the rear grille as shown 7 Center unit and gently slide unit into sleeve 8 Before sliding all of the wa...

Страница 17: ...ition 5 Attach 2 1 x 3 8 x 14 seals to the left and right sides of the sleeve 6 Cut 2 1 x 3 8 x 25 long seals to 14 long and attach to the vertical sections of the rear grille as shown 7 Center unit a...

Страница 18: ...3 8 x 14 seals to the left and right sides of the sleeve 6 Cut 2 1 x 3 8 x 25 long seals to 14 long and attach to the vertical sections of the rear grille as shown 7 Center unit and gently slide unit...

Страница 19: ...ension into the room 9 Attach 1 x x 14 long seal over the solid vertical portion of the rear grille 10 Attach 2 4 x 3 x 1 foam blocks with the slot overlapping the seal above 11 Install the divider in...

Страница 20: ...h 1 1 x x 14 long seal vertically 4 5 from the left side of the sleeve Attach the other 1 x x 14 long seal from the right slide of the sleeve 5 Center unit and gently slide unit into sleeve 6 Before s...

Страница 21: ...sion into the room 8 Attach 1 x x 14 long seal over the solid vertical portion of the rear grille 9 Attach 2 4 x 3 x 1 foam blocks with the slot overlapping the seal above 10 Install the divider into...

Страница 22: ...of screw holes are at the bottom b The fins of the grille are pointed away from the unit 3 Align the top of the grille with the top of the unit and ensure that the overhang on each side is equal 4 If...

Страница 23: ...he unit A flat bladed screwdriver or putty knife is recommended 3 Pull cord through trim frame then slide in unit until flush with wall 2 Assemble the trim frame by inserting top and bottom pieces int...

Страница 24: ...e air filter Never attempt to operate the unit without the air filter Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth o...

Страница 25: ...an filter Refer to Care and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher...

Страница 26: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in PRC 877 365 6274 www per...

Отзывы: