background image

Содержание 2PAMSH18-MZ02

Страница 1: ......

Страница 2: ......

Страница 3: ...ce technician or certified HVAC contractor for installation of this unit Contact an authorized service technician or certified HVAC contractor for repair or maintenance of this unit This appliance is...

Страница 4: ...inlet and outlet vents Never attempt to repair relocate or modify the air conditioner yourself Always contact your qualified service provider if required Do not operate your air conditioner in a wet e...

Страница 5: ...w the air conditioner to run for too long with the doors or windows open or if the humidity is very high If the air conditioner is to be used in conjunction with other heaters the air should be refres...

Страница 6: ...amp For Cooling Heating models only Lights up when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation 1 Front panel 2 Top air in...

Страница 7: ...ISPLAY PANEL OPERATION indicator The indicator flashes once every second after power is on and illuminates when the air conditioner is in operation TIMER indicator The indicator illuminates when TIMER...

Страница 8: ...ication lamp This indicator appears only when the compressor is in operation and indicates the current operating frequency TIMER indication lamp Lights up during Timer operation DEFROST indication lam...

Страница 9: ...cting pipe 11 Connective cable 12 Stop valve 13 Fan hood 10 11 12 13 Indoor unit 6 5 7 8 1 2 3 4 Air outlet Air inlet 1 Panel frame 2 Rear air intake grille 3 Front panel 4 Air filter behind 5 Horizon...

Страница 10: ...hen the warm air control feature is activated in heating operation TIMER display Displayed during Timer operation TURBO operation display Displayed when select TURBO function on cooling operation or o...

Страница 11: ...anual are for explanation purposes only Your air conditioner may be slightly different The actual shape shall prevail Indication lamp on LED Display window OPERATION indication lamp This lamp illumina...

Страница 12: ...ting operation 1 Front panel 2 Air inlet 3 Air filter inside 4 Air outlet 5 Horizontal air flow grille outside 6 Horizontal air flow grille inside 7 Vertical air flow louver 8 Display panel 9 Manual c...

Страница 13: ...ton is used to operate the unit temporarily in case you misplace the remote controlor its batteries are exhausted One press of the manual control button will lead to the forced AUTO operation If press...

Страница 14: ...FAN indication lamp Lights up when the air conditioner starts defrosting automatically in heating operation applicable to cooling heating models only or fan only mode is selected applicable to coolin...

Страница 15: ...rosting automatically in heating operation applicable to cooling heating models only or fan only mode is selected applicable to cooling only models 5 6 7 8 5 TEMPORARY button This button is used to op...

Страница 16: ...2 4 3 OPERATION lamp This indicator illuminates when the unit is operational TIMER indication lamp Lights up during Timer operation ALARM indication lamp Flashes when malfunction occurs PRE DEF FAN in...

Страница 17: ...unit will operate under forced COOL operation Close the panel firmly to its original position 1 3 2 NOTE The unit must be turned off before operating the manual control button If the unit is operation...

Страница 18: ...er is connected to power initial power the horizontal louver may generate a sound for 10 seconds this is a normal operation CAUTION Range Range Vertical louver Adjust the air flow direction properly o...

Страница 19: ...outlet parts sold separately are used with the indoor unit Heating To effectively heat the bottom of the room please set the louver downwards Cooling To effectively cool the whole room please adjust...

Страница 20: ...peration 7 hours timer off 7 hours timer off To achieve optimal performance please note the following Adjust the air flow direction correctly so that it is not directed at occupants Adjust the tempera...

Страница 21: ...ry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Handle Cleaning the air filter A clogged air filter reduces the cooling efficiency...

Страница 22: ...HVAC contractor Check that the wiring is not broken off or disconnected Check that the air filter is installed Check if the air outlet or inlet is blocked after the air conditioner has not been used...

Страница 23: ...ody must be disconnected before completely removing intake grille DUCT TYPE 2 Take out the air intake grille 3 Remove the air filter 4 Clean the air filter A vacuum cleaner or pure water may be used t...

Страница 24: ...escape away from the flange fixed holes and take off the filter according to the arrow direction shows in Fig G2 3 Clean the air filter A vacuum cleaner or pure water may be used to clean the air fil...

Страница 25: ...as just starting B Defrosting C Low temperature heating The indoor or outdoor fan stop running when defrosting Cooling and heating models only Defrosting Cooling and heating models only Frost may be g...

Страница 26: ...gher Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed 8 Heating mode For cooling and heating models only The air conditioner draws in heat from the outdoor uni...

Страница 27: ...ower cut Fuse may have blown Battery in Remote Control may be exhausted You have set a timer function Wait for power to be restored Replace the fuse Replace the battery Wait or cancel timer setting Se...

Страница 28: ...erformance data is subject to change without notice Printed in China 844 472 2473 www perfectaire us PA Manual_Gen2MZMSOutdoorUser 01182018 Distributed by C L L e r i A t c e f r e P 5401 Dansher Rd C...