Page 11
Indoor Unit
Installation
Step 5: Adjust the air inlet direction
(From rear side to under-side.)
1. Take off ventilation panel and flange, cut off
the staples at side rail.
2. Stick the attached seal sponge as per the
indicating place in the following fig, and then
change the mounting positions of air return
panel and air return flange .
Air return flange
Side rail
Dentilation panel
Seal sponge
3. When installing the filter mesh, fit it into the
flange inclined from air return opening, and
then push up.
4. The installation has finish, upon filter mesh
which fixing blocks have been insert to the
flange positional holes.
NOTE:
All the figures in this manual are for
demonstration purposes only. The air conditioner
you have purchased may be slightly different in
design, though similar in shape.
Step 6: Fresh air duct installation
Dimension :
Duct joint for fresh air
80mm(3.15”)
80mm(3.15”)
Ø90mm(3.54”)
Ø125mm(4.92”)
Ø160mm(6.3”)
MODLE
12-24
30-60
Step 7: Motor and drain pump maintenance
Motor maintain:
Take off the ventilated panel.
Take off the blower housing.
Take off the motor.
1.
2.
3.
(the rear ventilated panel is used as an example)
Mofor
Blower housing
Ventilated panel
Pump maintainance:
Remove four screws from the drain pump.
Unplug the pump power supply and water
level switch cable.
Detach the pump.
1.
2.
3.
Pump