 STEP 3:

INSTALL THE AIR CONDITIONER IN THE WINDOW

•  Open window and mark center of window sill (See FIG. 8.)

•  Place cabinet in window. Bring window down temporarily behind upper guide to hold cabinet in place. Shift cabinet 

left or right, as needed, to line up center of cabinet with the center line marked on sill. 

This may require 2 people.

•  Check that the air conditioner is tilted back approximately 3°~4° downward to the outside. 

If the condensation does not 

drain after installation, adjust the slope.

 (See FIG. 9.)

•  Fasten cabinet to window sill with 3 wood screws (B) into holes. (You may wish to pre-drill pilot holes.)

•  Attach bottom rail seal over screws to window sill. (See FIG. 10.)

WOODEN WINDOWS

INSIDE

OUTSIDE

H: APPROX. 
1” TO 1 3/8” 
FOR 12,000 
BTU UNITS

H

MEASURE FROM THE CABINET EDGE

FIG. 8

FIG. 9

FIG. 10

CENTER LINE

BOTTOM 

RAIL SEAL

WOOD 

SCREW (B)

FOR STORM WINDOWS

•  Remove the storm window and add wood, as shown, before 

installing the air conditioner. (See FIG. 11.)

•  If the storm window frame must remain, be sure the drain holes 

or slots are not caulked or blocked. Rain water and condensation 

must be able to drain out. 

 STEP 4: 

INSTALL SUPPORT BRACKET

•  Hold the support brackets flush against outside of sill and tight to the bottom of cabinet, as shown below. Mark 

brackets at top level of sill, then remove. (See FIG. 12.)

•  Assemble sill angle bracket with bolts (J) provided at the marked position, as shown. Hand tighten, but allow for 

changes later. (See FIG. 13.)

•  Install support brackets (with sill angle brackets attached) to correct hole in bottom of cabinet with screw, washer and 

lock nut (I) provided. (See FIG. 14.)

•  Securely tighten all 6 bolts.

SCREW

(I)

(I)

LEFT

(J)

RIGHT

SCREW, WASHER & LOCKNUT

LOCKNUT

LOCKNUT

SILL ANGLE

BRACKET

FLAT

HEAD

BOLT

WASHER

FIG. 12

FIG. 13

FIG. 14

MARK

INNER

SILL

OUTER SILL

FOR STORM WINDOWS

WOOD FOR

INNER SILL

STORM 

WINDOW

FRAME

WOOD

STRIP

FIG. 11

Содержание 1PEC12000

Страница 1: ...WINDOW AIR CONDITIONER FOR MODEL 1PEC12000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...an installer for installation of this unit The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with th...

Страница 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Страница 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Страница 6: ...before installation Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing...

Страница 7: ...just the horizontal air direction 9 FRONT GRILLE Air filter is located behind the front grille 10 UP DOWN ADJUSTMENT Hold the up down air flap and manually move it upward or downward to your desired p...

Страница 8: ...r conditioner must have clear air space to allow enough airflow through the condenser for heat removal The rear of the unit must be outdoors not inside a building or garage Inner sill Offset Window Si...

Страница 9: ...ACCORDION PANELS Place cabinet on the floor a bench or a table Remove the top rail and accordion panels from the carton Place them on a flat surface Align the holes in the top rail with those on the...

Страница 10: ...L WOOD SCREW B FOR STORM WINDOWS Remove the storm window and add wood as shown before installing the air conditioner See FIG 11 If the storm window frame must remain be sure the drain holes or slots a...

Страница 11: ...his unit Installation of front panel is the reverse of removal outlined in Remove Chassis on page 6 STEP 7 SECURE THE AIR CONDITIONER SEE FIG 17 Extend the accordion panels to fill the window opening...

Страница 12: ...MP TIME buttons to set the time on the display from 1 24 hours in 1 hour increments The TIMER ON OFF indicator will be on when the timer has been set TIMER OFF Turn the unit on to set the desired temp...

Страница 13: ...ol panel reminding you to clean the filter Press this button to turn off the CHECK FILTER LED light on the unit and reset the check filter timer for 250 hours 11 TIMER Button Press this button to set...

Страница 14: ...lace the air filter back into the grille If the air conditioner is operated without an air filter screen the interior of the unit will be contaminated with dirt which may cause performance failure or...

Страница 15: ...creen and install it back in place 4 Clean the unit Use a soft dry cloth to wipe the air conditioner or use a vacuum cleaner to do the cleaning If the air conditioner is very dirty you may use a cloth...

Страница 16: ...hten tube away from coil Make sure nothing is blocking the grille or side vents Make sure there is no dirt or debris inside the unit or on the filter UNIT WILL NOT TURN ON Reset circuit breaker Make s...

Страница 17: ...REVIEW THE CHART BELOW ISSUE POSSIBLE CAUSES FOG IS BLOWN OUT DURING THE COOLING OPERATION When the indoor temperature and humidity is high this may occur When the indoor temperature and humidity dro...

Страница 18: ......

Страница 19: ......

Страница 20: ...Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_1PEC...

Отзывы: