ST-01 Speed gate, STD-01 Double-sided section
After
sending
“Single passage in a set direction”
command speed gate intrusion detectors
control the presence of a user in the passageway. After completing the passage, the speed
gate switches to the
“Always locked”
mode.
After sending
“Single passage in a set direction”
command, if the passage was not
performed or another command was not sent, speed gate swing panels get closed
automatically after
Holding in unlocked state
(8 seconds by default) expiration, the speed
gate switches to the
“Always locked”
mode.
After sending
“Single passage in a set direction”
command, if the passage was not
performed, the command can be resent and
Holding in unlocked state
countdown starts
again.
After
sending
“Single passage in a set direction”
command, the
“Free passage”
command
for the other direction will be ignored.
After
sending
“Free passage in a set direction”
command, only
“Always locked”
or
“Single
passage in a set direction”
command for the opposite direction can be sent, all other
commands will be ignored.
9.3 Potential control mode
Speed gate control command sending and its indication are performed according to Table 8.
Passage directions are independent of each other, i.e. sending a command for one direction does
not change the opposite passage direction mode.
Table 8. Potential control mode
Indication
Command
Required to ensure
RC-panel
Central post
Speed gate state
“Both
directions
closed”
High level on
Unlock A
and
Unlock B
contacts
(or low level on
Stop
contact
)
Red
“Stop”
indicator
is on
Red for both
directions
Swing panels are
closed
“Direction
open”
Low level on the contact
of the chosen direction.
High level on all other
contacts
Green indicator of
the chosen
“Left”
/
“Right”
direction is
on
Green for the
chosen
direction
Swing panels turn in
the passage
direction
“Both
directions
open”
Low level on
Unlock A
and
Unlock B
contacts.
High level on
Stop
contact
Both green
“Left”
and
“Right”
indicators are on
Green for
both
directions
Swing panels are
open until receiving
the new command
9.4 In case of an emergency
9.4.1 “Emergency” mode
In case something interferes with the free rotation of the swing panels, the speed gate
automatically switches into “Emergency” mode. This mode is required to avoid motor drive failure,
caused by overheating.
If there is an obstacle, interfering with the swing gate rotation in the set direction, three turns in the
same direction with a 3 seconds interval are performed. If the obstacle is not removed, the speed
gate switches to the “
Emergency
” mode. In “Emergency” mode speed gate swing panels can turn
freely at a ±90º angle, which allows removing the obstacle from the passage lane with ease. In this
case all three light indicators of the RC-panel are on and sound indication of 3 short sound signals,
with a period of 20 seconds each is on.
“Emergency” mode is switched off automatically after the obstacle is removed, the speed gate
passage lane is freed and the swing panels are set into an initial (closed) position.
The “
Alarm
” signal is automatically generated if the passage lane of the speed gate is occupied by
something or someone for more than 30 seconds. The signal will be deactivated after the passage
lane is cleared.