Operation Manual
6
As a part of ACS, the controller provides:
•
operation in ACM: “
Open
”, “
Control
”, “
Security
”
Closed
”;
•
saving the set mode in the non-volatile memory in order to avoid the turn-off of the mode in
case of power failure;
•
support of local and global control of zonality, double-check and verification;
•
connection of light and sound alarm devices;
•
possibility of arming and disarming of the protected zone;
•
sending alarm notifications to the central surveillance panel.
5.2 Controller boards
Figure 1. The upper and lower controller boards
The controller features two boards – upper board (processor module) and lower board (process
execution module). The
XS1
–
XS2
terminal blocks of the upper board are connected to the
XP1
–
XP2
connectors of the lower board. The controller boards are shown in Fig. 1. The terminal blocks
application is given in the Table 1.
The upper board of the controller features:
•
X1
– microSD-card slot;
•
S1
– connector for the
Ethernet
cable;
•
X3
– connector for USB0 equipment
;
•
X4
-
connectors for USB1 and USB2 equipment;
•
XP1
– connector to choose the method of the IP-address of the controller; by default, the
jumper is not installed - user mode (Sect. 5.3);
•
XS1, XS2
– connectors for connecting to the lower board.
The lower board of the controller features:
•
XP1, XP2
– connectors for connecting to the upper board;
1
The mode “
Security
” is available only for “Controller for lock control” configurations and connected
CL-201
lock controllers.