8.2.5 RC-panel connection
The controller in the relevant configuration allows connecting up to two RC-panels to control
turnstiles, swing gates or vehicle checkpoint ODs. To connect each RC-panel to the controller the
following inputs can be used:
•
Three inputs to control the passage:
DUA, DUSt, DUB
;
•
Three outputs to control the RC-panel indication:
LdA, LdSt, LdB
.
The RC-panel #1 is to be connected to the contacts of the
XT2
terminal block, the RC-panel #2 is
connected to the contacts of the
XT10
terminal block (Fig. 10)
.
The
DUA, DUSt
and
DUB
inputs
in these configurations of the controller are activated by low-level
signals (normally open contact) relative to
GND
contact. Signal settings that can be used for
connection of the RC-panel are specified in Sect. 5.4.2 and 5.5.3.
Figure 10. Connection layout of RC-panel or WRC of “Turnstile control”
and “Vehicle checkpoint control” configurations
8.2.6
Fire Alarm
device connecting
In case of fire alarm or other emergency situation, there is possibility of automatic unlocking
(passage opening) of all ODs connected to the controller board and the controllers of the second
level except ODs which are in
“Security”
operating mode (the possibility of emergency unlocking is
to be configured at the configuration).
Emergency release (emergency passage opening) of ODs is produced by the command of the
Fire
Alarm
emergency device. The
Fire Alarm
emergency device is connected to the
FA
input of the
controller (
FA
contacts and
GND
of
XT2
terminal block contacts, Fig. 3, 5, 10). If the device
Fire
Alarm
is not used, wire jumper (installed by default) is to be installed at the input. Settings for
FA
signal are indicated in Sect. 5.4.2. When the control signal is applied to the
FA
input
,
the controller
operates in the
Fire Alarm
mode. In this mode, all connected devices open for passage in both
directions. Other control commands are ignored.
8.2.7 Optional equipment connection
To connect optional equipment, follow the following recommendations:
1. The typical connection layouts of the optional equipment are shown in Fig. 11, 12, 13.
2. To connect the optional equipment, use cable type #4 (Table 3).
3. Fix cables with plastic ties to self-adhesive cable tie mount, included into delivery set, by
installing them inside the controller housing.