CT/L-04.2 Controller Web-Interface
1. WEB-INTERFACE OPPORTUNITIES
Using Web-interface without installation of additional software allows performing following
steps for the controller and connected devices:
Change configurations, access password and time of built-in clocks of the controller.
Configure Settings of operational device, readers and other equipment’s of the
controller.
Set ACM for operation devices.
Record the access card numbers in the controller memory, assign them the rights for
arming or disarming.
Monitor event log of the controller and save them as a file.
Control the status of the controller and connected devices, monitor the event log.
Troubleshoot the controller, format the memory and update the embedded software.
Attention!
It is possible only with the Web-interface:
Select controller configuration and Settings of built-in memory (access
cards/events).
Add and delete the controllers of second level in configuration.
Add and delete optional readers in configuration.
Note:
Change of configurations via Web-interface of the controller is not available if the
controller is under control of network or local software of
PERCo
systems (you can
only monitor the configuration; operations are forbidden). The access to Web-
interface is allowed if the software is configured to
Allow Web-interface
. It is
possible after stopping the operation of the software and stopping the server of
PERCo
system.
2. CONNECTION TO WEB-INTERFACE OF THE CONTROLLER
Connection between the controller and the computer is performed via
Ethernet
interface
(IEEE 802.3). Make sure that the computer and the controller are on the same subnet
Ethernet
. It may become necessary to change network settings of the computer, browser
settings and to check operation of the network. IP-address of the controller is specified in
the certificate and the controller board.
To connect the controller to Web-interface:
1. Open Web-browser (e.g.
Internet Explorer
).
Note:
Web-interface was tested with the Web-browsers:
Microsoft IE
version 10 or higher,
Google Chrome
version 32 or higher,
Mozilla Firefox
version 32 or higher,
Opera
version 30 or higher,
Microsoft Edge
and for
MacOS
Apple Safari 9
or higher. If you
use other browsers and outdated versions, malfunctions of the Web-interface can
appear.
2. Enter in the address bar IP-address of the controller and press the button
Enter
on the
keyboard. If necessary, enter the access password to the controller. By default, there
is no password. When entering the password, the content of the field
User name
doesn’t matter.
51
Содержание CT/L-04.2
Страница 1: ...Controller CT L 04 2 ASSEMBLY AND OPERATION MANUAL...
Страница 2: ...Controller CT L 04 2 Assembly Operation Manual...
Страница 22: ...CT L 04 2 Controller Figure 3 Common scheme of connections 21...
Страница 26: ...CT L 04 2 Controller Figure 6 Connection schemes of Turnstile control configuration 25...
Страница 32: ...CT L 04 2 Controller Figure 13 Connection scheme of optional equipment to controller inputs 31...
Страница 44: ...CT L 04 2 Controller Figure 15 Scheme of connection of the card capture reader IC 02 1 43...
Страница 45: ...Assembly Operation Manual Figure 16 Scheme of connection of the card capture reader IC 05 44...
Страница 70: ...www perco com...