MAINTENANCE
Parts of wear of the pump
To protect the quality of your device, we advise you (*) to change the rooms of following wears:
MEASURED PRODUCTS FREQUENCY
CODE
NAME
pH- or pH+
2 years
Peristaltic tube 6*9mm
Crystal PVC tube, 4x6
4 years
Roller holder 6*9mm + bearing kit + front cover
Complete 2-in-1 sensor holder
Chlore
1 years
Peristaltic tube 6*9mm
2 years
Roller holder 6*9mm + bearing kit + front cover
Complete 2-in-1 sensor holder
Crystal PVC tube, 4x6
4 years
Strainer
(*) the frequency of replacement of rooms(parts,plays) is indicative, she can vary according to conditions of use
6.1
General
Over time, in addition to the normal wear and tear of the electrode, depending on the use and the quality of the
more or less calcareous water, the measurement will deteriorate. A thin film of limescale will be deposited on the
sensitive element of the probe together with other elements present in the pool water. To overcome this problem,
we recommend using the cleaning solution for pH or redox electrodes AYACSOLNET02 and following the procedure
indicated on the bottle.
6.2
Chlorine injection valve maintenance
Periodically check that the injection valve is not clogged. A precipitate forms in the injection valve in contact with
chlorine and the lime contained in the water. After a certain time depending on the chlorine used and the lime
content in the water, the valve will clog. In this case the peristaltic tube may burst and drain the chemical or the
engine may break. This is an external problem to our equipment, these damages are not covered under warranty.
Clean the chlorine
deposit from the
injection tube with acidic
water or replace the PVC
Содержание iQntrol DOS-ECO
Страница 1: ...www peraqua com DOS ECO INSTRUCTIONS AND USER MANUAL...
Страница 13: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 13 Positioning on a vertical pipe...
Страница 21: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 21 STEP 12 Installation of the probe pH J1 and Rx J2 2 3 1...
Страница 32: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 32 6 3 Installation of a long probe 120 mm J G P 1 2 3...