INSTRUCTIONS AND USER MANUAL 

 

Содержание iQntrol DOS-ECO

Страница 1: ...www peraqua com DOS ECO INSTRUCTIONS AND USER MANUAL...

Страница 2: ...scription 9 3 RECOMMENDATIONS AND INSTALLATION 9 3 1 Recommandations 9 3 2 Hydraulic and electrical installation principle 10 3 3 Device Dimensions 11 3 4 Device installation 11 4 ADVANCED DEVICE SETT...

Страница 3: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 3 6 3 Installation of a long probe 120 mm 32 6 4 Peristaltic tube replacement 33 6 5 Wintering 33 7 AFTER SALE SERVICE 34 8 SPARE PARTS LIST 35...

Страница 4: ...lve foot filter and peristaltic hose WARNING any intervention or repair to the internal parts of the pump must be carried out by qualified and authorized personnel The manufacturers decline all respon...

Страница 5: ...efore be used for applications that were not allowed for in its design In case of doubt please contact our offices for further information about the characteristics of the pump and it proper use The m...

Страница 6: ...diately be brought to a stop emptying and depressurizing the delivery hos while taking all due the safety precautions gloves goggles overalls etc 1 5 Toxic and or dangerous liquid dosage To avoid risk...

Страница 7: ...ts configuration 2 1 Parts description The complete list of accessories delivered with the equipment is given below All the parts will be necessary for the correct operation of your unit A1 pH4 pH7 ca...

Страница 8: ...f selections Long press Increases a numerical value quickly Short press Switch from one display to an other Exit current menu Long press Give access to the installation configuration with SET Increase...

Страница 9: ...o a few weeks and oxidise the pump s s metallic parts In this case the warranty is voided The stabilizer rate must be less than 15 ppm in order not to disturb the reading of the redox The use of chlor...

Страница 10: ...control of the swimming pool circulation pump E Pool water circulation pump F Pool G Pool filtration i Electrical cable for wire detection connected in electrical box D Warning Under no circumstances...

Страница 11: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 11 3 3 Device Dimensions Height 260 mm Width 220 mm Depth 130 mm 3 4 Device installation STEP 1 Mounting the housing 220 mm 260 mm...

Страница 12: ...g tool F Positioning on a horizontal pipe 1 Remove the sensor s protective cap and keep it to re use it for the winter shutdown period 2 Leave the sensor submerged in tap water for at least 20 minutes...

Страница 13: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 13 Positioning on a vertical pipe...

Страница 14: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 14 STEP 4 Preparation of the probe holder Mount the O ring H under the support flange B Remove the cap and store 1 2...

Страница 15: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 15 STEP 5 Position the support flange by inserting the injection pipe in the direction of flow 1 2 Q 3...

Страница 16: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 16 STEP 6 Attachment to the pipe 50 pipe 63 pipe C L K K C L O...

Страница 17: ...A2 in parallel with the coil of the filter pump relay The voltage to be applied to this cable is 230V This means that the unit will only be supplied with power when the filter pump is switched on 2 C...

Страница 18: ...L Connecting the suction lances to the unit 2 protective covers for Jack sockets Remove the 2 protective covers from the sockets Jack Plug the Jack plug into the socket If you remove the suction lance...

Страница 19: ...water CALIBRATING pH 4 4 25pH 90s 7 25 is an example of instantaneous measurement before calibration values are commonly between 6 5 and 7 5 6 9pH SET CAL 6 9pH 720mV 720mV SET CAL Tip PRESS THE ESC K...

Страница 20: ...100 475mV press OK 720mV SET CAL Tip PRESS THE ESC KEY AT ANY TIME TO EXIT THE CALIBRATION PROCEDURE 6 9pH 720mV After pressing OK the unit continues operating normally 462mV is an example of instanta...

Страница 21: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 21 STEP 12 Installation of the probe pH J1 and Rx J2 2 3 1...

Страница 22: ...refer to the following chapters to adjust the advanced settings as required Cut tube J to connect foot filter E to the left inlet of the pump and probe holder D to the right inlet of the pump Place fo...

Страница 23: ...E VALUE WILL BE MEMORIZED Setting range of 6 5 to 7 6 pH 6 9pH SET CAL 6 9pH 720mV 720mV SET CAL Tip To adjust the chlorine setpoint press one more time the MENU ESC SETPOINT 700mV WHEN THE SET BUTTON...

Страница 24: ...setpoint the longer the instrument activates the dosing The closer the measured value is to the desired value setpoint the shorter the dosing time Pool size Pump Acti Time S 0 1 pH Pump Acti Time S mV...

Страница 25: ...FLOW RATE pH pump flowrate information no setting OVERDOSING ALARM Refer to section Erreur Source du renvoi LANGUAGES FRAN AIS ENGLISH DEUTSCH NEDERLANDS PORTUGUES ESPAGNOL ITALIANO MEASURE OFFSET Fr...

Страница 26: ...mp flowrate setting 1 5 by default adjustable from 0 1 to 99 9 l h OVERDOSING ALARM Refer to section 4 4 4 LANGUAGES FRAN AIS ENGLISH DEUTSCH NEDERLANDS PORTUGUES ESPAGNOL ITALIANO PUMP ACTIVA TYPE PR...

Страница 27: ...NY TIME TO EXIT MENU EXTERNAL INPUT ON by default OFF CONFIGURATION SYS TECHNICAL DETAIL NO TECHNICAL DETAIL YES NO Displays the offset and gain measurements for the after sales service LANGUAGES FRAN...

Страница 28: ...d OVERDOSING ALARM 0 05 l 4h Adjusting the overdose alarm above the defined threshold the pump enters a state of alarm and requires that the CAL OK button be pressed to start again To disable the alar...

Страница 29: ...to save power A short press of SET or CAL turns it on 5 SOLUTIONS TO PROBLEM 5 1 Incorrect measure and procedure for increasing the TAC If the displayed value on the device differs from the value obta...

Страница 30: ...rresponding reservoir with fluid MEASURE TOO LOW pH mode measured pH 5 pH REDOX mode mesurement 100 mV Check pool water parameters TAC 100 mg L Check the status of the probes cable MEASURE TOO HIGH pH...

Страница 31: ...ity of the more or less calcareous water the measurement will deteriorate A thin film of limescale will be deposited on the sensitive element of the probe together with other elements present in the p...

Страница 32: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 32 6 3 Installation of a long probe 120 mm J G P 1 2 3...

Страница 33: ...one grease 6 5 Wintering 6 5 1 Pum wintering It is important to know that for the winter shutdown of your unit it is the peristaltic tube that needs protecting It is then recommended to pump clean wat...

Страница 34: ...filled to 1 3 with AYACSOLSTK01 storage solution and the protective cap placed on the sensor s extremity This assembly must be stored away from freezing conditions at ambient temperature 7 AFTER SALE...

Страница 35: ...10 RPM 230 240 Vac motor 3L h pump 7 6 9mm peristaltic tube 8 Roller holder kit transparent cover tube 6x9 9 pH probe Rx probe 10 EPDM 11 9 X 2 62 O rings per 10 units 11 2 in 1 probe holder 12 Probe...

Страница 36: ...uctions and user manual DOS ECO NOT041ENV01_FP1 PERAQUA Handelsstra e 8 4300 St Valentin Austria Mail info peraqua com Web www peraqua com Instruction and user manuals are included with new products N...