Commissioning

6.6

Request byte for reading heads

F0=0: The reading head sends the position data to the interface module. This standard function 
is automatically active after commissioning.

F0=1: The reading head sends the result of the diagnostic function.

For more information on the function of F0 see chapter 7.

6.7

Data format of WCS-PNG110 interface module for the reading heads

In "only Position" mode, 4 bytes are reserved for each reading head.

In "Position and Speed" mode, 6 bytes are reserved for each reading head.

To see what the data bit means see chapter 7.

reading head 

address 3

reading head 

address 2

reading head 

address 1

reading head 

address 0

Bit

7

6

5

4

3

2

1

0

0

F0

0

F0

0

F0

0

F0

Bit

7

6

5

4

3

2

1

0

Input a 4x reading 
head a 0

0

0

0

0

0

P18

P17

P16

Input a 4x reading 
head a 1

P15

P14

P13

P12

P11

P10

P09

P08

Input a 4x reading 
head  2

P07

P06

P05

P04

P03

P02

P01

P00

Input a4x reading 
head a 3

0

0

0

DB

ERR

OUT

A1

A0

Table 6.3: Data format for each connected reading head in "only Position" mode, reading head 
address = 0 ... 3

Bit

7

6

5

4

3

2

1

0

Input a 6x reading 
head a 0

0

0

0

0

0

P18

P17

P16

Input a 6x reading 
head a 1

P15

P14

P13

P12

P11

P10

P09

P08

Input a 6x reading 
head a 2

P07

P06

P05

P04

P03

P02

P01

P00

Input a 6x reading 
head a 3

0

0

0

DB

ERR

OUT

A1

A0

Input a 6x reading 
head a 4

0

0

0

0

0

0

0

0

Input a 6x reading 
head a 5

0

S06

S05

S04

S03

S02

S01

S00

Table 6.4: Data format for each connected reading head in "Position and Speed" mode, 
reading head address = 0 ... 3

Содержание WCS-PNG110

Страница 1: ...WCS PNG110 WCS PROFINET INTERFACE MODULE FACTORY AUTOMATION MANUAL...

Страница 2: ...Terms of Delivery for Products and Services of the Electrical Industry published by the Central Association of the Electrical Industry Zentralverband Elektrotech nik und Elektroindustrie ZVEI e V in i...

Страница 3: ...5 1 Mounting 8 5 2 Electrical connection 8 6 Commissioning 10 6 1 Cable routing in the RS 485 bus 10 6 2 Meaning of LEDs 13 6 3 Connecting the reading heads 14 6 4 Connecting the WCS PNG110 to the ne...

Страница 4: ...on a worldwide scale Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any questions about the...

Страница 5: ...2 2009 04 5 2 Declaration of conformity 2 1 CE conformity This product was developed and manufactured under observance of the applicable European standards and guidelines Note A declaration of conform...

Страница 6: ...ent interventions and separate modifications are dangerous and will void the warranty and exclude the manufacturer from any liability If serious faults occur stop using the device Secure the device ag...

Страница 7: ...the reading head and the interface module via an RS 485 interface The data from the interface module to the PLC is transferred using the PROFIBUS protocol You can connect a maximum of four WCS readin...

Страница 8: ...tion Note Grounding of the mounting rail The mounting rail must be grounded to the switch cabinet The connection wire must have a cross section of at least 10 mm2 Reading head WCS LS221 WCS PNG110 PRO...

Страница 9: ...age 10 30 V DC to terminals 1 and 2 of the 4 pin connector X2 on the interface module The Power LED lights up green Terminal Designation 1 UB Pwr Operating voltage interface module operating voltage r...

Страница 10: ...This in line connection must end with a terminator The RS 485 terminators are integrated in the WCS reading heads and can be switched on and off with the interface module If only one reading head is c...

Страница 11: ...and one reading head at the end of the data line With two reading heads the RS 485 terminator is activated The interface module is located between these two heads and does not have an RS 485 terminato...

Страница 12: ...ion between the interface module and the first reading head through a short spur length 1 m Use bus terminal BT111 to connect the spur Figure 6 3 Connection of two reading heads Version B The wiring v...

Страница 13: ...progress The PROFINET State LED flashes green PROFINET initialized The PROFINET State LED flashes red Error during PROFINET initialization The PROFINET State LED lights up red PROFINET hardware error...

Страница 14: ...tion instructions for the reading head if you need to change the address of the reading head The number of connected reading heads and their mode of operation is configured by the hardware project set...

Страница 15: ...The GSD file can be downloaded from our website http www pepperl fuchs com Terminal Designation 1 TD Transmission line 2 TD Transmission line 3 RD Receive line 4 5 6 RD Receive line 7 8 Table 6 2 Term...

Страница 16: ...me during the configuration process If you are using more than one interface module on the network you must assign each interface module a name that will enable the PLC to uniquely identify the device...

Страница 17: ...s the network to see which PROFINET nodes are present Broadcast query A list of the connected devices is displayed in the window Changing the device name 1 Stop PROFINET communication if it is active...

Страница 18: ...evice name and save the configuration The PLC will recognize the name of the device and will be able to communicate with it Note An LED on the device can be made to flash using the configuration tools...

Страница 19: ...In Position and Speed mode 6 bytes are reserved per reading head configuration data for 4 reading heads 0x20 0xD2 0xD2 0xD2 0xD2 Setting the number of reading heads operating mode and addresses 1 Open...

Страница 20: ...F0 Bit 7 6 5 4 3 2 1 0 Input address 4x reading head address 0 0 0 0 0 0 P18 P17 P16 Input address 4x reading head address 1 P15 P14 P13 P12 P11 P10 P09 P08 Input address 4x reading head address 2 P0...

Страница 21: ...displays the result of the self diagnosis of the reading head 7 2 Data from reading head Meaning of A1 and A0 Function number for reading head F0 0 send position value F0 Function number for reading h...

Страница 22: ...1 x Error message from reading head error message binary coded in P00 P04 ErrorNo Select ID LED Error number Designation 8 4 2 1 0 1 1 1 7 Communication reading head send buffer overflow 1 0 0 0 8 Com...

Страница 23: ...WCS PNG110 Appendix 202342 2009 04 23...

Страница 24: ...6 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Pacific Headquarters Pepperl Fuchs Pte Ltd Com...

Отзывы: