Product Description
Front Panel
Figure 2.3
Front panel overview
WCS read head: LED status indicator and rotary coding switch
Power:
The "Power" LED lights up green: power supply is present.
State:
The "State" LED is green: Data is being exchanged with the WCS read heads. The four "Error
No/Select ID" LEDs are used to display the number of the currently polled WCS read head.
The "State" LED lights up red: The interface module has detected an error or a warning. The
interface module displays the binary-coded error and/or warning number via the "Error
No/Select ID" LEDs.
Error No/Select ID
Read head
address
8
4
2
1
0
0
0
1
0
0
0
1
0
1
0
1
0
0
2
1
0
0
0
3
Table 2.1
Display via the four "ErrorNo/Select ID" LEDs when the "State" LED lights up green
Error (No. 1...5):
Switch the interface module off and back on. If the error occurs
again, the module must be replaced.
Warning (No. 6...15):
The warning provides information. The interface module displays
the warning for one minute and then resets automatically.