AS-i 3.0 EtherNet/IP Gateway with integrated Safety Monitor
Operation in advanced display mode
This menu shows the status of the safety AS-i safe slaves and the diagnostics for
the integrated Safety Monitor for each release circuit separately.
9.6.3.2
LAST DIAGNOSIS (Last diagnostics for the int. monitor)
Main menu || DIAGNOSIS || INT MONITOR ||
LAST DIAGNOSIS
||
INT SAFETY MON
DIAGNOSIS
CH 1.: ON
...
ASI 1
SLAVES
| 1-XX
2-RX | 3-RR
4- | 5-
....
A COLOR
32 RED
....
HELP:
X CHANNEL OK
R CH. RELEASED
A DEVICE ADR.
COMPLETE: The complete diagnostic is read out.
DIAG INDEX: The diagnostic is shown as it was configured under the
"device_Index_Assignment" in ASIMON.
Information!
If the diagnosis is read using DIAG INDEX, the device count begins at 0, otherwise at
32!
INT MONITOR
DIAGNOSIS
LAST DIAGNOSIS
VIEW CONFIG