2
0
1
8
-0
9
9
Motor Direction of Rotation Indicator
Status Indicators for Sensors IN1, IN2, IN3, IN4
The LED IN1 for input 1, LED IN2 for input 2, LED IN3 for input 3, and LED IN4 for input 4
indicate the switch states of the inputs.
Display of the Inputs
2.4
Interfaces and Connections
Flat Cable Specification
The AS-Interface motor control module is compatible with the AS-Interface standard cable in
accordance with IEC 62026-2.
The following AS-Interface cable types with "UL Recognized" approval are available:
AS-Interface Cable Types with UL Approval
Input/Output Connections
The sensors and motors are connected to the motor control module via cables with round M8
connectors:
■
Sensors: socket, 4-pin
■
Motors: socket, 5-pin
The cable length is 0.5 m.
LED DIR
Yellow
Status
On
Direction of rotation to the right (ITOH Denki)
Off
Direction of rotation to the left (ITOH Denki)
LED IN1
LED IN2
LED IN3
LED IN4
Yellow
Status
On
Input is set (high)
Off
Input is not set (low)
Fuchs
Designation
Color
Sheathing/wire
insulation material
Cross section UL "Cable Style"
Approval
VAZ-FK-R-YE
Yellow
TPE/TPE
2x 1.5 mm
2103
VAZ-FK-R-BK
Black
TPE/TPE
2x 1.5 mm
2103
VAZ-FK-PUR-YE
Yellow
PUR(TMPU)/TPM
2x 1.5 mm
20549
VAZ-FK-PUR-BK Black
PUR(TMPU)/TPM
2x 1.5 mm
20549