201
5-0
3
112
Pulscon LTC57 PROFIBUS PA
Operating menu
15.3.4
Level submenu
Level
Medium type
Medium property
Navigation
Setup
Advanced setup
Level
Navigation
Setup
Advanced setup
Level
Medium type
Description
Specify type of medium.
User interface
• Liquid
• Solid
Factory setting
• LTC50, LTC51:
Liquid
• LTC57:
Solid
Additional information
The
Solid
option is only available for
Operating mode
=
Level
Note:
This parameter determines the value of several other parameters and
strongly influences the complete signal evaluation. Therefore, it is strongly
recommended
not to change
the factory setting.
Blocking
Navigation
Setup
Advanced setup
Level
Medium property
Prerequisite
EOP level evaluation
Fix DC
Description
Specify relative dielectric constant
r
of the medium.
Selection
• Unknown
• DC 1.4 to 1.6
• DC 1.6 to 1.9
• DC 1.9 to 2.5
• DC 2.5 to 4
• DC 4 to 7
• DC 7 to 15
• DC > 15
Factory setting
Dependent on
Medium type
(page 112) and
Medium group
.
Additional information
Dependency on
Medium type
and
Medium group
Medium type
Medium group
Medium property
Liquid
Water based (DC >= 4)
DC 4 to 7
Others
Unknown
Solid
–
Unknown
Note:
Dielectric constants of important media commonly used in the industry are
summarized in the technical information (TI).
Note:
For
EOP level evaluation
=
Fix DC
, the exact dielectric constant has to be
entered into the
DC value
parameter. Therefore, the
Medium property
parameter
is not available in this case.