Troubleshooting
2
02
0-
01
19
9
Troubleshooting
9.1
Faults when programming the output
If unexpected situations occur when the output of the inductive angular positioning system is
programmed, refer to the table below for possible causes and instructions for rectifying the
problem.
State
Possible cause
Action
Sensor cannot be moved in
programming mode (relevant
yellow LED does not flash
when a button is pressed).
Button not pressed long
enough.
Press the button for program
-
ming the output
2 s.
Sensor cannot be moved in
programming mode
("Power/Error" LED lights up
red).
No actuator available or own
actuator mounted too far away
from the surface of the sensor.
Mount actuator according to
specifications (see chapter
5.2).
"Power/Error" LED lights up
red during programming.
Actuator lost during the
parameterization process or
distance between actuator
and surface of sensor too
great (own actuator).
Make sure that the concentric
-
ity and adjustment of own
actuator does not result in a
loss of the actuator (see chap
-
ter 5.2).
LED stops flashing during the
programming process.
Timeout while programming
the output (1 minute after the
last input).
Move sensor again in pro
-
gramming mode ( or )
After programming, the func
-
tion of the output/outputs
remains unchanged.
Programming process not
completed within the time
frame (1 minute) or incorrect
button pressed during pro
-
gramming.
Complete the programming
process by pressing the corre
-
sponding button for the output
a third time within the time
frame ( or )
A yellow LED flashes and the
"Power/Error" LED flashes red
at the same time.
The button assigned to the
flashing yellow LED is stuck.
Remove any dirt or foreign
objects that are causing the
key to stick.