Installation
5.4
PROFIBUS Connection
The PCV... read head is connected to PROFIBUS via a 5-pin M12 x 1 connector (
Bus in
) and a
5-pin M12 x 1 socket (
Bus out
), located on the side of the housing.
Figure 5.9
Figure 5.10
For details of suitable PROFIBUS cables, see chapter 4.3.
Caution!
Damage to the device
Connecting an alternating current or excessive supply voltage can damage the device or cause
the device to malfunction.
Electrical connections with reversed polarity can damage the device or cause the device to
malfunction.
Connect the device to direct current (DC). Ensure that the supply voltage rating is within the
specified device range. Ensure that the connecting wires on the female cordset are connected
correctly.
Connector Assignment
1
2
3
4
5
1
2
3
4
5
5 V ISO
BUS-A
BUS-GND ISO
BUS-B
SHIELD
B
u
s
o
u
t
n.c.
BUS-A
n.c.
BUS-B
SHIELD
B
u
s
in
1
5
3
2
4
Bus out
1
5
3
4
2
Bus in