Operation and Communication

 2

0

1

6

-1

2

9

4

Operation and Communication

4.1

Communication via PROFINET

4.1.1

General Information on Communication via PROFINET

PROFINET is an open standard for industrial automation based on industrial Ethernet. 
PROFINET integrates information technology with established standards such as TCP/IP and 
XML in automation technology.

The communication concept for setting up decentralized applications within PROFINET is 
PROFINET IO, i.e. decentralized field devices are integrated by PROFINET IO. The familiar IO 
view of PROFIBUS DP is used where the usable data of the field devices is transferred to the 
controller process image in cycles. PROFINET IO is a device model consisting of slots and 
channels, which is based on the main features of PROFIBUS DP. The field device properties 
are written in a GSDML (generic station description markup language) based on XML. 
PROFINET IO is engineered in the same way as has long been the case for system integrators 
of PROFIBUS DP. The decentralized field devices are assigned in the design of a controller.

PROFINET IO draws a distinction between three device types: IO controller, IO device, and IO 
supervisor.

IO controller: Controller that executes the automation program.

IO device: Decentrally assigned field device that is assigned to an IO controller.

IO supervisor: Programming unit/PC with commissioning and diagnostic functions.

4.1.2

PROFINET IO Interface

OHV-F230-B17 gateways are PROFINET IO devices that communicate cyclically with the 
assigned PROFINET IO controller during operation.

The PROFINET interface of the OHV-F230-B17 gateway supports:

A transfer rate of 100 Mbit/s

The real-time category RT

The range of functions in accordance with 

Conformance Class B

The identification and maintenance functions (I&M) IM0 

 IM4

Identification & Maintenance Data

Identification and maintenance data (I&M data) is information stored in a device. I&M data 
uniquely identifies a device within a system. The identification data (I data) includes information 
about the device, for example the item number and device name. Identification data cannot be 
changed.

Maintenance data (M data) includes information regarding the device within the system, for 
example the installation location and installation date. Maintenance data is initially stored in the 
device during installation; this data can be changed.

Data Input

The Step7 software from Siemens can be used to display and change the I&M data. You can 
read and write I&M data 1, 2 and 3 in the "Target System" menu of the HW Config hardware 
configuration using the functions "Download Module Identification" and "Download Module 
Identification to PG".   

 see Figure 4.1 on page 10.

Содержание OHV-F230-B17

Страница 1: ...R OHV F230 B17 PROFINET Gateway for OHV Handheld FACTORY AUTOMATION MANUAL...

Страница 2: ...erms of Delivery for Products and Services of the Electrical Indus try published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in it...

Страница 3: ...ndicators 6 2 4 Interfaces 7 2 5 Accessories 7 3 Commissioning 8 4 Operation and Communication 9 4 1 Communication via PROFINET 9 4 1 1 General Information on Communication via PROFINET 9 4 1 2 PROFIN...

Страница 4: ...he documentation may comprise the following parts if applicable EC Type Examination Certificate EC Declaration of Conformity Attestation of conformity Certificates Control drawings Other documents 1 2...

Страница 5: ...d in descending order as follows Informative Symbols Action This symbol indicates a paragraph with instructions You are prompted to perform an action or a sequence of actions Danger This symbol indica...

Страница 6: ...an integrated switch The handheld reader is supplied with power by the gateway 2 2 Dimensions Figure 2 1 2 3 Indicators The following indicators can be found on the OHV F230 B17 gateway 33 5 47 136 6...

Страница 7: ...ach In 3 UB GND 4 Trigger In PROFINET 1 2 1 Tx 2 Rx 3 Tx 4 Rx RS232 1 TX 2 n c 3 CTS 4 RX 5 RTS 6 Trigger Out 5 V Imax 100 mA 7 GND 8 5 V Imax 500 mA RS485 1 Trigger Out 24 V Imax 200 mA 2 UB Imax 1 A...

Страница 8: ...held reader 1 Connect the OHV1000 F223 R2 and OHV100 F222 R2 handheld readers to the gateway using the V19S G 1 7 3M PVC V50 connection cable 2 Connect the gateway to the power supply 3 Scan the contr...

Страница 9: ...program IO device Decentrally assigned field device that is assigned to an IO controller IO supervisor Programming unit PC with commissioning and diagnostic functions 4 1 2 PROFINET IO Interface OHV F...

Страница 10: ...PROFINET network Import the GSD file into a project planning tool Peripheral addresses are assigned to the individual channels of the field devices The peripheral input addresses incorporate the recei...

Страница 11: ...230 B17 instance data block Right click on the marked entries and select Copy 3 Right click the destination project and select Insert Connecting the gateway to the S7 control panel 1 Before installing...

Страница 12: ...e 4 3 Inserting PROFINET IO system A PROFINET IO system is now available to which you can connect new nodes 8 Drag the PROFINET module of the gateway from the catalog into the connection window and li...

Страница 13: ...module just inserted select Destination system Ethernet Edit Ethernet node from the menu bar In the window that opens click Browse A list opens containing all accessible nodes Figure 4 5 Browsing PRO...

Страница 14: ...en previously is present in the section Assign device name in this example ohv f230 click Assign name 13 Click Close 14 Double click the PROFINET module in the connection window and check whether the...

Страница 15: ...2016 12 15 Figure 4 7 PROFINET module properties 15 Click OK 16 To assign address areas for inputs and outputs add the following modules from the catalog to the device Result counter Result 64 byte F...

Страница 16: ...ng modules enable gateway data to be retrieved using PROFINET Result counter 32 bit module The result counter increments a 32 bit value when a handheld reader has sent a result to the gateway Result 6...

Страница 17: ...yte 125 End of the scan result Byte Content Bit no 7 6 5 4 3 2 1 0 Status byte 0 Status byte ND1 1 New data flag Changes when the gateway receives new data from the scanner and makes it available for...

Страница 18: ...43 4B 75 K 6B 107 k 0C 12 FF 2C 44 4C 76 L 6C 108 l 0D 13 CR 2D 45 4D 77 M 6D 109 m 0E 14 SO 2E 46 4E 78 N 6E 110 n 0F 15 SI 2F 47 4F 79 O 6F 111 o 10 16 DLE 30 48 0 50 80 P 70 112 p 11 17 DC1 31 49 1...

Страница 19: ...chs GmbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia P...

Отзывы: