26
6859
201
4-
04
12 - EN
Warning Device NVD-111
Installation
EN
3
Installation
3.1
Mounting of the Sensors
Read the chapter on Safety and, in particular, the section on Installation and
Commissioning (see chapter 1.7) before mounting the sensor. Do not remove the
identification plate.
During installation, read the instructions provided by the grease interceptor
manufacturer. Ensure that the suspension mechanism keeps the sensor
permanently at the correct height. Where possible, secure the device in a position
where it can be reached from the manhole opening so that it can be removed
when emptying (disposal) or carrying out maintenance work on the grease
interceptor.
The oil/petrol separator can be made of various materials. We therefore
recommend using the following methods to secure the device in a suspended
position:
n
If mounting the device in concrete containers, use the NVO5-B mounting
set. See the figure below.
n
If mounting the device in containers made from other materials, such as
plastic or metal, use other suspension devices as appropriate, for example,
screws and screw anchors.
Warning!
Risk of short circuit
Injuries and damage to the device are possible when working with live parts.
n
Before working on the device, always disconnect the supply voltage.
n
Connect the device to the supply voltage only after completion of the work.
Warning device NVD-111