Страница 1: ...LC10 Laying loops for Loop detector LC10 1 and LC10 2 FACTORY AUTOMATION MANUAL ...

Страница 2: ... Terms of Delivery for Products and Services of the Electrical Indus try published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its most recent version as well as the supplementary clause Expanded reservation of proprietorship Manual LC10 ...

Страница 3: ...e and Application 3 3 Indicators and Operating Controls 3 3 1 LC10 1 3 3 2 LC10 2 3 4 Interfaces and connections 3 5 Dimensions 4 Installation 4 1 Preparation 4 1 1 Laying loops 4 1 2 Number of loop windings 4 1 3 Loop test 4 2 Installation 5 Commissioning 5 1 Test function 5 2 Loop geometry 5 3 Loop interference 5 4 Influencing variables 6 Troubleshooting ...

Страница 4: ...3 Manual LC10 ...

Страница 5: ...rtificate EU declaration of conformity Attestation of conformity Certificates Control drawings Additional documents 1 2 Target Group Personnel Responsibility for planning assembly commissioning operation maintenance and dismounting lies with the plant operator Only appropriately trained and qualified personnel may carry out mounting installation commissioning operation maintenance and dismounting ...

Страница 6: ...d in descending order as follows Informative Symbols Action This symbol indicates a paragraph with instructions You are prompted to perform an action or a sequence of actions Danger This symbol indicates an imminent danger Non observance will result in personal injury or death Warning This symbol indicates a possible fault or danger Non observance may cause personal injury or serious property dama...

Страница 7: ...uctions before attempting commissioning Caution Installation connection and adjustments should only be undertaken by specialist personnel Warning No safety component for protection of personnel or EMERGENCY STOP functions EU Directive Standards 2014 30 EU EN 61000 6 2 2005 EN 61000 6 4 20071A1 2011 2014 35 EU EN 60204 1 20061A 1 2009 ...

Страница 8: ... below the surface forms the inductor of a high frequency oscillating circuit The metal parts of a vehicle that enters or is located in this wired loop cause the frequency of the oscillation circuit to change This frequency change is analyzed by the loop detector and the outputs which are zero potential relay contacts can switch The switching outputs are relay contacts with a high switching power ...

Страница 9: ...ing the switches 1 and 2 Operating mode switches The following operating modes can be set with switches 5 and 6 1 LED indicator 2 DIP switch switch 3 switch 4 sensitivity OFF ON low ON OFF medium ON ON high Table 3 1 In the switch position OFF OFF the loop evaluation is switched off switch 1 switch 2 frequency OFF OFF basic frequency f ON OFF f 10 OFF ON f 15 ON ON f 20 Table 3 2 After actuation o...

Страница 10: ...op detector can be set in three stages using switches 3 and 4 for loop 1 and switches 5 and 6 for loop 2 Frequency switches The loop frequency can be set in four stages using the switches 1 and 2 1 LED indicator loop 2 2 LED indicator loop 1 3 DIP switch switch 3 or 5 switch 4 or 6 sensitivity OFF ON low ON OFF medium ON ON high Table 3 4 In the switch position OFF OFF the loop evaluation is switc...

Страница 11: ...cated before loop 2 only one switch signal is output for loop 1 The signal output for loop 2 remains inhibited until both loops are free again If loop 2 is allocated before 1 only one switch signal is output for loop 2 The signal output for loop 1 remains inhibited until both loops are free again The increased sensitivity Boost is used for the detection of vehicles with high body assemblies e g HG...

Страница 12: ... 2 Dimensions LC10 1 and LC10 2 Number Explanation Connector terminals 4 Loop connection Loops 1 2 7 8 loop 1 8 9 loop 2 5 Signal output Loop 1 5 6 NO 6 10 NC 6 Signal output Loop 2 3 4 NO 4 11 NC 7 Operating voltage 1 2 7 8 6 4 1 10 5 11 3 2 5 6 7 4 9 SL 1 SL 2 SL 1 SL 2 75 37 5 27 71 ...

Страница 13: ... detector The connection lead should not exceed a length of max 150 m Laying loops under composite paving When laying loops under composite paving the loop must be laid permanently in a plastic pipe in a sand bed We recommend to lay the loops in a plastic conduit The loop must not be laid in groove cut into the composite paving 4 1 2 Number of loop windings The induction loop consists of several c...

Страница 14: ...talled directly in switch cabinets They can be fixed either on a 35 mm top hat rail or via screw connections Direct installation at the induction loop on location is also possible through integration in an ISO housing This method of installation is recommended for long loop connection leads During switch cabinet installation care must be taken not to install the loop detectors directly next to swi...

Страница 15: ...he loop The loop detector measures and stores the frequency change When switches 3 and 4 are changed over the recommended sensitivity is indicated by flashing of LED 1 Loop 1 In addition to LC10 2 When switches 5 and 6 are changed over the recommended sensitivity is indicated by flashing of LED 2 Loop 2 Measurement of the loop frequency The loop frequency can be measured via the LED Set switches 3...

Страница 16: ...nected to different loop detectors must have a minimum distance of 2 meters from each other and operate on different frequencies For loops connected to a double detector this minimum distance can be reduced However it must be ensured that the two loops do not operate on the same frequency roadway driving direction 2 m 1 m roadway driving direction 0 9 m 0 2 m 45 Sliding doors Selection gates Foldi...

Страница 17: ...stances should not exceed 5 The cross section of the loop connection lead should be 1 5 mm Steel reinforcements Steel reinforcements in the floor reduce the loop sensitivity With heavy reinforcements the loop size should be adjusted optimally to the vehicle size no large loops in order to keep the loss of sensitivity low Laying loops The loops must be permanently laid in the floor to prevent malfu...

Страница 18: ...aying instructions for inductive loops Fault Analysis Source of Fault Cause Action By using a two channel loop detector both channels are responding identically Both detectors are working on the same frequency Different inductive loops in length and number of loops must be installed and connected The loop detector doesn t react or has contact issues The connections are dirty Please clean the conne...

Страница 19: ...chs Group 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Pacific Headquarters Pepperl Fuchs Pte Ltd Company Registration No 199003130E Singapore 139942 Tel 65 67799091 E mail sales sg pepperl fuchs com DOCT0973C 11 2016 ...