IDENT-I • IVI-KHD2-4HB5, IVI-KHA6-4HB5
Commissioning an S5 135U with INTERBUS-S interface
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
D
a
te
of
is
su
e
3
0.
07
.2
0
0
1
43
11.4.7 BB1: image block
Input words 20 ... 26 and output words 30 ... 36 are displayed by calling up image
block BB 1 in the PG function "Control variables".
The input and output data of the analyser unit can be interpreted here.
The appropriate commands can be sent to the analyser unit by changing the output
words.
The handbook for the analyser unit is to be used for interpreting the contents.
Output word OW 30 must follow output words OW 32 ... OW 36 so that the parameters
are written to the appropriate output words before a command is transmitted.
11.5
Blocks
11.5.1 OB1 structure
;cyclic program
SPA
FB 62
NAME:
CON/IND
IBDB:
DB 9
CIDB
MB 18
;InterBus data blocks
T :
T 1
;Head-DB-CON/IND
TO :
M 8.3
;Timer
;Timeout
U
M 10.0
SPB
FB 72
NAME:
ADDRESS
IBDB
DB 9
BUSY
M 10.=
;InterBus data block
T :
T 2
;Activation-Bit
IDDB:
DB 10
;Timer
IDDW:
KF +0
;DB: ID-code list
LBDB
DB 11
;DW:
LBDW
KF +0
;DB: Bus-segment list
INDB:
DB 12
;DW:
INDW
KF +0
;DB: IN-address list
OUDB:
DB 13
;DW:
OUDW
KF +0
;DB: OUT-address list
KRDB
DB 0
;DW:
KRDW:
KF +0
;DB: KR-address list
GRDB:
DB 0
;DW:
GRDW:
KF +0
;DB: group definitions
MODE:
M 10.5
;DW:
EREG:
MB 12
;indicator mode