2
01
9-
07
8
Functional Safety HiD2872, HiC2873(Y1), HiD2876, HiC2877
Product Description
HiC2873Y1
This device is a 1-channel device.
The device is bus powered.
The device is controlled with a switch contact, transistor, or logic signal.
At full load, 12 V at 40 mA (with 55 mA current limit) is available for the hazardous
area application.
This device mounts on a HiC termination board.
HiD2876
This device is a 2-channel device.
The device is loop powered or bus powered.
It is controlled with a loop powered control signal, switch contact, transistor, or logic signal.
At full load, 11.2 V at 40 mA (with 55 mA current limit) is available for the hazardous
area application.
An alternative low current output is available for driving a single LED without installing
an external current limiting resistor.
This device mounts on a HiD Termination Board.
HiC2877
This device is a 1-channel device.
The device is loop powered or bus powered.
It is controlled with a loop powered control signal, switch contact, transistor, or logic signal.
At full load, 11.2 V at 40 mA (with 55 mA current limit) is available for the hazardous
area application.
This device mounts on a HiC termination board.