Functional Safety HiC2871A
Planning
3.3
Safety Function and Safe State
Safe State
The safe state of the output is the de-energized state. The output current is less
than 50
A.
Safety Function
When the input signal is active, the output is activated. The safe state is
introduced when the input voltage is below 5 V DC.
Reaction Time
The reaction time for all safety functions is < 1 s.
Note!