2
0
2
1
-0
5
10
Installation
3
Installation
3.1
Mounting the Read Head
Mount the read head on the auto-guided transport system using the four screws on the mount-
ing adapter on the read head. Mount the read head so that the lens with ring light and camera
module are aligned toward the floor.
The mounting must be stable enough so that the read head does not leave its depth of focus
range during operation.
The distance between the read head and the floor should be the same as the read distance of
the read head.
Optimum Read Distance
Read Head Dimensions
Figure 3.1
Housing dimensions
Model number
Read distance [mm] Depth of focus [mm]
Field of vision (w x
h) [mm]
PGV100R*
100
±
30
115 x 73
7
0
8
0
38.5
70
2
2
3
5
9
4
x
M
6
Caution!
When selecting the length of the mounting screws, ensure that the maximum insertion depth of
the screws in the threaded inserts on the read head is 8 mm.
Using longer screws may damage the read head.
Caution!
The maximum torque of the mounting screws must not exceed 9 Nm.
Tightening the screws to a higher torque may damage the read head.