3RG72563NQ00PF Distance sensor 06813787 / 453489 Stand: 03/2011
Mounting and
operating instructions
42
Byte n°
Description
Data
4
Function 1
High byte
D8: trigger input
D9:Q
1
is enable input
D10: X
D11: Maximum hold
D12: Difference hold
D13: Q
1
is software input
D14: fast meas. value output
5
Function 1
Low byte
D0: Q
1
is signal output
D1: Q
1
is scanning zone
D2: Q
1
is signal output inversion (1 = N.C.)
D3: Q
1
is signal output pulse stretching
D4: Minimum hold
D5: Autom. zero
D6: Autom. centre
6
Function 2
High byte
D8 ... D14: Identification of variants
7
Function 2
Low byte
D0: Q
1
is signal output
D1: Q
1
is scanning zone
D2: Q
1
is signal output inversion (1 = N.C.)
D3: Q
1
is signal output pulse stretching
D4: Q
2
is good target output
D5 ... D6: X
8
Function 3
High byte
D8: Measured value hold
D9, D10: X
D11: Key lock
D12 ... D14: X
9
Function 3
Low byte
D0: Mean value 0.4 ms
D1: Mean value 4 ms
D2: Mean value 40 ms
D3 ... D6: X
10
Characteristic curve 0% High byte
See 1)
11
Characteristic curve 0% Low byte
See 1)
12
Characteristic curve 100% High byte
See 1)
13
Characteristic curve 100% Low byte
See 1)
14
Switching threshold Q
1
High byte
See 1)
15
Switching threshold Q
1
Low byte
See 1)
16
Scanning zone Q
1
High byte
See 1)
17
Scanning zone Q
1
Low byte
See 1)
18
Switching threshold Q
2
High byte
See 1)
19
Switching threshold Q
2
Low byte
See 1)
20
Scanning zone Q
2
High byte
See 1)
21
Scanning zone Q
2
Low byte
See 1)
Explanations on bus commands
1)
Highbyte
Lowbyte
0
0
D11
D10
D9
D8
D7
D6
0
0
D5
D4
D3
D2
D1
D0
D0 D11 = distance value 0 4095 (according to the set measuring range)
2)
Byte
0
D6
D5
D4
D3
D2
D1
D0
3)
Highbyte
Lowbyte
0
GT
D11
D10
D9
D8
D7
D6
0
Q1
D5
D4
D3
D2
D1
D0
D0 D11 = distance value (0 4095)
Q1 = status of Q1
GT = Good Target
4)
Highbyte
Lowbyte
0
1
D11
D10
D9
D8
D7
D6
0
0
D5
D4
D3
D2
D1
D0
D0 D11 = distance value (0 4095)
Bit6 = 1: High byte
Bit6 = 0: Low byte
5)
After input of “?”, the sensor setting is transmitted as follows: