ENERAL SPECIFICATIONS 

&

 PARAMETERS

 

Nominal input:   

  

110VAC / 220VAC; 50/60Hz 

Input range: 

 

  

105-132VAC / 200-248VAC; 50/60Hz 

Phase Current   

 

 

6.0A/110V 

(at nominal output power/ voltage)  

3.0A/220V 

Output:   

 

 

Model  UA12V10ART 

 

12VDC / 10A  

Model  UA18V18ART  

 

18VDC / 18A  

Model  UA12V25ART  

 

12VDC / 25A   

 
Efficiency 

 

 

>= 85% 

Operating Temperature   

+5ºC - +40ºC 

Dimensions 

 

 

10x150x260mm (WxHxD) 

Weight   

 

 

1.9kg 

 
Adjustable voltage stabilization mode: 
Output Voltage Adjustment: 
UA12V10ART 

 

 

0.35VDC - 12VDC  

UA12V25ART 

 

 

0.35VDC - 12VDC  

UA18V18ART 

 

 

0.35VDC - 18VDC 

Output Voltage Accuracy   

 

 

 

<= 0.2% 

Output Voltage Adjustment Resolution (step) 

 

10mV 

Output Voltage Ripple and Noise (under maximum load) 

<= 1% 

Instability of Terminal Voltage Output 

 

 

<= 1% 

(Depends on external factors) 

 

 
Adjustable load current stabilization mode: 
Load Current Adjustment: 
UA12V10ART 

 

 

0.01 - 10A  

UA12V25ART 

 

 

0.01 - 25A  

UA18V18ART 

 

 

0.01 - 18A 

Load Current Accuracy 

 

 

 

 

<= 1%  

Load Current Adjustment Resolution (step)  

 

10mA 

Load Current Ripple and Noise (under maximum load) 

<= 1% 

Instability of Load Current  

 

 

 

<= 1% 

(Depends on external factors) 

 

 
Timer adjustment 
Maximum Time   

 

 

9hrs 59min 

Adjustment Precision 

 

 

1 second 

 
Pulse Voltage mode 
Positive / Negative Pulse Duration  

0.1 - 90min 

Adjustment Precision 

 

 

1 second 

 
Heater Input/output  
Heater Nominal Power   

 

140W  

Temperature units (User Selectable) 

C° / F° 

Temperature Range 

 

 

1°– 85°C / 33° - 185°F 

Temperature Adjustment (step)   

1°C /1°F 

Содержание IPS Series

Страница 1: ...stem with intuitive and easily configurable programming No other devices on the market offers anywhere near the range of features precision or affordability as Pepetools IPS When using Pepetools Professional Intelligent Power Supply even the most challenging galvanic operations are perform with ease precision and professional results Included in the box 1 Intelligent Power Supply IPS 1 AC Power Co...

Страница 2: ...2 Disconnect the Power cord from the outlet SAFETY INSTRUCTIONS Do not expose the PS to rain or moisture Do not disassemble the device Do not jerk the power cord Do not block the ventilation holes Place PC on a flat stable surface and at least 4 100mm away from the walls for good air circulation Do not place heavy objects on the PC When IPS not used for an extended period disconnect the AC cord We...

Страница 3: ...Voltage Adjustment Resolution step 10mV Output Voltage Ripple and Noise under maximum load 1 Instability of Terminal Voltage Output 1 Depends on external factors Adjustable load current stabilization mode Load Current Adjustment UA12V10ART 0 01 10A UA12V25ART 0 01 25A UA18V18ART 0 01 18A Load Current Accuracy 1 Load Current Adjustment Resolution step 10mA Load Current Ripple and Noise under maximu...

Страница 4: ...ues Rotary encoder pushbutton short pressing enter in sub menu select deselect values in edit mode Rotary encoder push button pressing press and holding for more than 3 seconds will take you back to main menu and put the device into standby mode switch off power supply and heater LEDs Standby backlight LEDs ON Plating and or heatingbacklight front and side LEDs ON Error backlight front and side LE...

Страница 5: ...am de lay depending on the program setup NOTE Depending on configuration when some features are disabled missing or not used for example heating the menus for related option will not display The symbol t show current active process step Depending on state of process values show measured or rest of time to end of the step or pre set value Select program Short pressing and select program form 1 5 or...

Страница 6: ...disabled or missing for example out put voltage reverse menus for related option will not display Available if the device has a Heater option Setting Sequence program Configure program from Sequence programs 1 5 to execute sequentially Line 1 Select current active program Line 2 6 Step 1 5 select sequence of the programs Line 7 Exit Back to main menu Manual mode Manual control of plating heating o...

Страница 7: ...act the distributor were you purchased the unit or contact Pepetools im mediately Please have the following information about your unit available upon contacting Model Number and Revision located on the label on the back of the unit Unit s Serial Number located on the label on the bottom of the unit Line Voltage and frequency Detailed description of the problem encountered including load and ambie...

Страница 8: ...For additional information visit www pepetools com 8 ...

Отзывы: