Troubleshooting

Leaks:

...between cap and bottom of filter housing

Turn off water supply valve and turn on drinking water faucet to 

release pressure in system. Remove bottom of housing. Clean O-ring 

and O-ring groove (located directly beneath threads of housing). 

Lubricate O-ring with silicone grease and replace securely into 

groove. Screw bottom of housing onto cap and hand-tighten. DO NOT 

OVER-TIGHTEN. Turn on water supply valve and check for leaks. 

...on system inlet/outlet connections

Turn off water supply valve and turn on drinking water faucet to 

release pressure in system. Remove tubing from fitting (see NOTE 

under Step Six: Connecting the Supply Adapter on p.3) and make sure 

end of tubing is cut squarely and free of scratches or burrs. Reinsert 

tubing into quick-connect fittings, making sure to push securely until 

tubing hits a hard stop. Turn on water supply valve and check for 

leaks.

...on supply adapter connection

Turn off water supply valve and turn on drinking water faucet to 

release pressure in system. Loosen leaking threaded fitting on supply 

adapter or pull out leaking tubing from fitting. Inspect to see if plastic 

tubing is scratched or supply adapter was properly attached. If tubing 

is scratched, cut off 1/2" to 5/8" and reinstall per Step Six: Connecting 

the Supply Adapter. Reconnect tubing or tighten compression nut with 

fingers, then tighten nut snugly 1/2-turn with wrench. Turn on water 

supply valve and check for leaks.

...on faucet/tubing connection

Turn off water supply valve and turn on drinking water faucet to 

release pressure in system. Loosen and remove compression nut 

fitting on faucet stem. Make sure tubing is inserted firmly into end of 

faucet stem, then retighten compression nut with fingers until secure 

then tighten 1 turn with a wrench. Turn on water supply valve, then 

turn off faucet to check for leaks.

NOTE:

 If leaks persist, or if there are other leaks on system, turn off 

water supply. Call our technical support department at 800.861.8758.

Low Water Flow

1.   Check flow at faucet. The US-1500 system should fill a gallon jug 

in approximately 2 minutes. Flow rates will vary with individual 

household water pressure. 

2.   Check filter cartridge installation. Make certain both filter 

cartridges are properly oriented in filter housings (See Filter 

Cartridge Replacement).

3.   Check to be certain that the water supply valve is completely open 

(turn handle on valve counter-clockwise as far as it will go).

4.   Check flow through empty system. To do this, turn off water supply 

valve and turn on drinking water faucet to release pressure in 

system. Then remove filter cartridges from housings and screw 

housings back onto caps. Turn on faucet to check flow through 

empty system.  Flow should be about one to two gallons per 

minute. If flow is less than 0.4 gallons per minute, call Technical 

Support at 800.861.8758. 

5.   If flow through empty system is adequate, place one filter 

cartridge in system at a time and check flow to make sure 

cartridge is not clogged. Replace clogged cartridge if necessary.

6

Содержание US-1500

Страница 1: ...ty glasses Hand or electric drill cordless recommended 1 4 drill bit File Phillips head screwdriver Adjustable wrench or 7 16 open end wrench Tube cutters or utility knife If sink does not have hole f...

Страница 2: ...o accommodate the faucet CAUTION This procedure may generate dusts which can cause severe irritation if inhaled or come in contact with the eyes The use of safety glasses and respirator for this proce...

Страница 3: ...UTION Do not bend or crimp tube when inserting B Gently pull back on the tube to ensure it is connected properly If the tube comes out of tting cut a small section of the tube off and reconnect 6 Conn...

Страница 4: ...t of guide arrows approximately 5 8 16 mm 8 Installing the Battery A Remove cover on top of system Attach 9 volt battery included to connector then place battery in holder located to the left of the m...

Страница 5: ...e they need to be replaced Filter cartridge life varies depending on usage and or water conditions Changes in taste color and ow of the water being ltered indicate that the cartridge should be replace...

Страница 6: ...8 and reinstall per Step Six Connecting the Supply Adapter Reconnect tubing or tighten compression nut with ngers then tighten nut snugly 1 2 turn with wrench Turn on water supply valve and check for...

Страница 7: ...to manufacturer s instructions including replacement of lter cartridges Test Conditions Flow Rate as noted for lter system Inlet Pressure 60 psi 4 1 bar pH 7 5 1 Temperature 68 F 5 F 20 C 2 5 C Operat...

Страница 8: ...erial Number if any and a brief description of the problem TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW PENTEK DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED...

Отзывы: