Technical Support: 800.861.8758 (M-F 7:30 a.m. - 5:00 p.m. CST)

Specifications

Temperature Range: 

40–100°F (4.4–37.8°C)

Pressure Range: 

30–125 psi (2.1–8.62 bar)

Service Flow Rate @ 60 psi (4.1 bar):  0.6 gpm (2.3 L/min)
Rated Service Life: 

1,000 gallons (3,785L)

Dimensions: 

 9.18 in. x 4.70 in. x 12.72 in. 

(233 mm x 119 mm x 323 mm)

Weight: 

6 lbs. (2.7 kg) (filled with water)

Parts Included

•  Filter system with filter cartridges – P-250 Cartridge Set
•   Installation hardware 

(mounting screws, T-Adapter, quick-connect elbows)

•  Electronic monitor and 9-volt battery
•  Housing wrench
•  Lead-free drinking water faucet
•  1/4" plastic tubing

Precautions

WARNING:

 Do not use with water that is microbiologically unsafe 

or of unknown quality without adequate disinfection before or after 

the system. Systems certified for cyst reduction may be used on 

disinfected waters that may contain filterable cysts. 

CAUTION:

 Filter must be protected against freezing, which can 

cause cracking of the filter and water leakage.

CAUTION:

 The rubber O-ring provides the water-tight seal between 

the cap and the bottom of the housing. It is important that the O-ring 

be properly seated in the groove below the threads of the housing or a 

water leak could occur.

CAUTION:

 Because of the product’s limited service life and to 

prevent costly repairs or possible water damage, we strongly 

recommend that the bottom of all plastic housings be replaced every 

ten years.  If the bottom of your housing has been in use for longer 

than this period, it should be replaced immediately. Date the bottom of 

any new or replacement housing to indicate the next recommended 

replacement date.

Tools and Materials 

Required

•  Safety glasses

•   Hand or electric drill 

(cordless recommended)

•  1/4" drill bit

•  File

•  Phillips head screwdriver

 

•   Adjustable wrench or 7/16” 

open-end wrench

•   Tube cutters or utility knife 

If sink does not have hole 

for separate faucet:

•  Center punch

•  3/4" drill bit or hole saw

NOTE: 

•  For cold water use only.
•   Make certain that installation complies with all state and local 

laws and regulations.

•   The contaminants or other substances removed or reduced by 

the selected cartridge are not necessarily in your water. Ask your 

local water municipality for a copy of their water analysis, or have 

your water tested by a reputable water testing lab. 

•   After prolonged periods of non-use (such as during a vacation) it 

is recommended that the system be flushed thoroughly. Let water 

run for 5–6 minutes before using.

•   The filter cartridges used with this system have a limited service 

life. Changes in taste, odor, and/or flow of the water being filtered 

indicate that the cartridge should be replaced.

About Your PENTEK Dual Filtration 

System

Thank you for purchasing a PENTEK Dual Filtration System. With only 

minimal maintenance, your new system will provide you with safer, 

better-tasting water for years to come. The filter cartridges should be 

changed after every 1,000 gallons of use or once every twelve months, 

whichever comes first. Filter life will vary depending on usage and 

water conditions. Changes in taste, odor, and/or flow of the water 

being filtered indicate that the filter cartridges should be replaced. 

The Model US-1500 is Tested and Certified by NSF 

International against NSF/ANSI Standard 42 for the reduction 

of Taste and Odor, Chlorine, and Particulate Class I. Standard 

53 for the reduction of Lead, Mercury, VOC, Cyst, Asbestos, 

and Turbidity.

Monitored Dual Filtration System 

Installation and Operating Instructions 

Model US-1500 (with electronic monitor)

 

146600   JA05

Содержание US-1500

Страница 1: ...ty glasses Hand or electric drill cordless recommended 1 4 drill bit File Phillips head screwdriver Adjustable wrench or 7 16 open end wrench Tube cutters or utility knife If sink does not have hole f...

Страница 2: ...o accommodate the faucet CAUTION This procedure may generate dusts which can cause severe irritation if inhaled or come in contact with the eyes The use of safety glasses and respirator for this proce...

Страница 3: ...UTION Do not bend or crimp tube when inserting B Gently pull back on the tube to ensure it is connected properly If the tube comes out of tting cut a small section of the tube off and reconnect 6 Conn...

Страница 4: ...t of guide arrows approximately 5 8 16 mm 8 Installing the Battery A Remove cover on top of system Attach 9 volt battery included to connector then place battery in holder located to the left of the m...

Страница 5: ...e they need to be replaced Filter cartridge life varies depending on usage and or water conditions Changes in taste color and ow of the water being ltered indicate that the cartridge should be replace...

Страница 6: ...8 and reinstall per Step Six Connecting the Supply Adapter Reconnect tubing or tighten compression nut with ngers then tighten nut snugly 1 2 turn with wrench Turn on water supply valve and check for...

Страница 7: ...to manufacturer s instructions including replacement of lter cartridges Test Conditions Flow Rate as noted for lter system Inlet Pressure 60 psi 4 1 bar pH 7 5 1 Temperature 68 F 5 F 20 C 2 5 C Operat...

Страница 8: ...erial Number if any and a brief description of the problem TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW PENTEK DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED...