elevation difference(VD) will change too.But if collimate A0 with the second
method,vertical angle is locked in the direction where prism is located and
can’t range from up-and-down movement of telescope.
Operation steps
Keys
Display
1
Click “Offset” key.
【
Offset
】
2
Click
“ANG.Offset”
key in ejecting dialog
box.
3
Select “Free VA”(or
“Lock
VA”)
with
stylus
to
to
start
angle
offset
measurement.(User
makes a choice on
the
basis
of
own
demand)