Front View

Flow Direction Arrow

Dosage Lock Nut

Pressure Release Button

Dosage Adjustment

Suction Hose Nut

Chemical Injector Pump

Incoming

Water

Supply

Sediment Filter

35 Gallon

Solution Tank

Pump Foot Valve

Chemical Injector

Pump Tubing

Outgoing Water

to House

Install the Chemical Injector Pump onto the water supply after the Sediment Filter and before any other

filtration or softening system.

1. Determine the size and material of your incoming water supply line from the Sediment Filter System.

2. Mount the Chemical Injector Pump to the wall using the provided bracket. Line up the inflow and outflow connections with the    

  current water line.
3. Remove the two red thread protectors from inlets and discard. Injector Pump has 3/4" connections, two 1" bushings are included.

4. Plumb the Injector Pump into your water line. The arrow on the body of the Injector Pump shows the correct water flow direction.  
  The Injector Pump can be rotated to match your flow direction. The water should enter and exit the pump following the direction of  

  the arrow.

CHEMICAL INJECTOR PUMP AND SOLUTION TANK INSTALLATION

IMPORTANT

Chemical Injector Pump Installation

Solution Tank Installation

1. Remove the black cap from the opening on the Solution Tank.
2. Drill one 1/2” hole into the top of the Solution Tank. (Hole should be larger than tubing to allow air in)
3. Insert the end of the Chemical Injector Pump Tubing with the pump foot valve connected into the hole which was covered by the   
  black cap on the top of the Solution Tank.
4. Feed and pull the other end of the tubing through the drilled opening on the top of the Solution Tank.
5. Determine the length of Chemical Injector Pump Tubing required for the foot valve to reach 4" from the bottom of the Solution Tank  
  and cut tubing.
6. Connect the Chemical Injector Pump Tubing to the suction valve on the Chemical Injector Pump by removing the suction hose nut,  
  place nut over tubing, push tubing onto suction valve and tighten nut.
7. Fill the Solution Tank with 17 gallons of bottled water and proper number of cups of bleach based on the % concentration of Sodium  
  Hypochlorite noted on the bottle (see chart below.)

 12 

 17

 7  

  17

  6  

 17

 4.5 

 17

IMPORTANT

Ensure the Chemical Injector Pump Tubing is free of kinks and the Solution Tank is not

sitting directly on concrete. The cold temperatures held by concrete floors can separate your solution.

IRON & MANGANESE FILTER SYSTEM COMBO • 9

Содержание WF4-P

Страница 1: ...pentair com homewater IRON MANGANESEFILTERSYSTEM COMBO WF4 P WF8 P...

Страница 2: ...ng system which could increase the risk of fire or injury while using your home appliances Please consult a licensed electrician before attempting to install WARNING When adding a filtration softening...

Страница 3: ...Rings 2 Split Rings 2 and Connectors 2 1 PVC Tail Adaptor for Electronic Head Bypass 90 Degree 1 PVC Tail Adaptors also included Sediment Filter System Big Blue Filter Housing Mounting Bracket Phillip...

Страница 4: ...Chemical Injector Pump Tubing 1 1 Chlorine Test Strips Chemical Injector Pump 2 1 Bushings Included 1 1 Non Abrasive Auto Wax 4 oz Bottle 1 Pentair Whole House Carbon Filter 1 Pentair Whole House Iron...

Страница 5: ...House Filter Outgoing Water to House Water to Home Water Softener Alternative Bypass Solution Tank Water Filter Injection Pump Iron Manganese Filter Sediment Filter Iron Manganese Filter Water Soften...

Страница 6: ...ntly than shown If the arrows on your bypass valve s do not match the diagram remove the red arrows by pulling them straight up turn them 180 to match the drawing and push them back down onto the stem...

Страница 7: ...leting step 3 turn water off and allow the tank to settle with no water usage Repeat step 3 but reduce how fast you flush the tank Should you need to perform the above steps after the tanks are connec...

Страница 8: ...water 2 Attach the filter cover to the mounting bracket using the supplied bolt head screws and washers Make sure to properly orientate the IN and OUT to match your flow pattern 3 Attach the mounting...

Страница 9: ...ution Tank Installation 1 Remove the black cap from the opening on the Solution Tank 2 Drill one 1 2 hole into the top of the Solution Tank Hole should be larger than tubing to allow air in 3 Insert t...

Страница 10: ...lter Electronic Head Red Clips Tail Adaptors Bypass Valve Part Description Qty 1 PVC Tail Adaptor for Electronic Head Bypass 2 Top View Front View IN OUT Wall Wall Incoming Water Supply Sediment Filte...

Страница 11: ...t Filter Whole House Filter Outgoing Water to House Water to Home Water Softener Alternative Bypass Solution Tank Water Filter Injection Pump Iron Manganese Filter Sediment Filter Iron Manganese Filte...

Страница 12: ...Service Figure B In Bypass COMPLETE THE INSTALLATION Figure A In Service Figure B In Bypass 1 Turn on main water supply 2 Press Pressure Release Button on top of Injector Pump 3 Check for leaks 4 Peel...

Страница 13: ...inly useful if you have override set to something other than OFF and do not want the unit to regenerate during an extended absence Press the SCROLL BUTTON to advance to the next setting 3 Immediate Re...

Страница 14: ...IMPORTANT 12 17 7 17 6 17 4 5 17 ELECTRONIC HEAD CONTROL INFORMATION Power on LED A green LED is ON when power is applied to the control and the microprocessor is operating properly Service Required I...

Страница 15: ...ed it should be replaced 6 Place a new sediment filter onto the stand pipe in the blue filter housing 7 Screw the blue filter housing onto the filter cover hand tight Lightly snug the housing with the...

Страница 16: ...programming of the control Reprogram if necessary Verify the minimum and maximum water pressure Install a pressure reducer if necessary Replace the filter media every three to five years Systems used...

Страница 17: ...installation due to extra carbon dust Water is backfilling into the solution tank The check valve on the lower end of the pump is stuck in the open position Turn water off relieve pressure remove the...

Страница 18: ...eration schedule and reset the control 3 Replace the drive motor 4 Replace the flow meter 5 Replace the computer board 6 Replace the microswitches The valve cycles continuously Replace the microswitch...

Страница 19: ...to complete the warranty registration form online For details on your Pentair product warranty please visit Send to Pentair 2361 Mason Avenue Suite 100 Daytona Beach FL 32117 Phone 1 800 842 1635 Date...

Страница 20: ...R T to NSF ANSI Standard 42 for the reduction of Chlorine Taste Odor structural integrity NSF ANSI 61 for material safety The NaturSoft system is DVGW DW 9191 certified for 99 6 hard water scale preve...

Страница 21: ...ty of Pentair Third party registered and unregistered trademarks and logos are the property of their respective owners 4006043 RevBJL21 2361 Mason Ave Suite 100 Daytona Beach FL 32117 United States P...

Отзывы: