Front View
Flow Direction Arrow
Dosage Lock Nut
Pressure Release Button
Dosage Adjustment
Suction Hose Nut
Chemical Injector Pump
Incoming
Water
Supply
Sediment Filter
35 Gallon
Solution Tank
Pump Foot Valve
Chemical Injector
Pump Tubing
Outgoing Water
to House
Install the Chemical Injector Pump onto the water supply after the Sediment Filter and before any other
filtration or softening system.
1. Determine the size and material of your incoming water supply line from the Sediment Filter System.
2. Mount the Chemical Injector Pump to the wall using the provided bracket. Line up the inflow and outflow connections with the
current water line.
3. Remove the two red thread protectors from inlets and discard. Injector Pump has 3/4" connections, two 1" bushings are included.
4. Plumb the Injector Pump into your water line. The arrow on the body of the Injector Pump shows the correct water flow direction.
The Injector Pump can be rotated to match your flow direction. The water should enter and exit the pump following the direction of
the arrow.
CHEMICAL INJECTOR PUMP AND SOLUTION TANK INSTALLATION
IMPORTANT
Chemical Injector Pump Installation
Solution Tank Installation
1. Remove the black cap from the opening on the Solution Tank.
2. Drill one 1/2” hole into the top of the Solution Tank. (Hole should be larger than tubing to allow air in)
3. Insert the end of the Chemical Injector Pump Tubing with the pump foot valve connected into the hole which was covered by the
black cap on the top of the Solution Tank.
4. Feed and pull the other end of the tubing through the drilled opening on the top of the Solution Tank.
5. Determine the length of Chemical Injector Pump Tubing required for the foot valve to reach 4" from the bottom of the Solution Tank
and cut tubing.
6. Connect the Chemical Injector Pump Tubing to the suction valve on the Chemical Injector Pump by removing the suction hose nut,
place nut over tubing, push tubing onto suction valve and tighten nut.
7. Fill the Solution Tank with 17 gallons of bottled water and proper number of cups of bleach based on the % concentration of Sodium
Hypochlorite noted on the bottle (see chart below.)
12
17
7
17
6
17
4.5
17
IMPORTANT
Ensure the Chemical Injector Pump Tubing is free of kinks and the Solution Tank is not
sitting directly on concrete. The cold temperatures held by concrete floors can separate your solution.
IRON & MANGANESE FILTER SYSTEM COMBO • 9