System Protections / Error Codes
When a fault occurs, the fault icon in the main interface will flash. When an error occurs or the protec-
tion mode is set automatically, the wired controller will display an error code as below. To view fault
codes, swipe left and tap
. The fault log will be displayed. You can clear fault codes, after trouble-
shooting by tapping the trash can.
Code
Fault Message
Possible reasons
Remedy
P01
Inlet Temp. Sensor Fault
The inlet temperature sen-
sor is broken or short cir-
cuited.
Check or change the tem-
perature sensor.
P02
Outlet Temp. Sensor Fault
The outlet temperature
sensor is broken or short
circuited.
Check or change the tem-
perature sensor.
P04
Ambient Temp. Sensor Fault The ambient temperature
sensor is broken or short
circuited.
Check or change the tem-
perature sensor.
P05
Coil 1 Temp. Sensor Fault
The coil temperature sensor
is broken or short circuited.
Check or change the tem-
perature sensor.
P15
Coil 2 Temp. Sensor Fault
The coil temperature sensor
is broken or short circuited.
Check or change the tem-
perature sensor.
P07
Suction Temp. Sensor Fault
The compressor suction
temperature sensor is bro-
ken or short circuited.
Check or change the tem-
perature sensor.
P081
Discharge Temp. Sensor
Fault
The compressor discharge
temperature sensor is bro-
ken or short circuited.
Check or change the tem-
perature sensor.
P082
Exhaust Air over Temp Prot.
The compressor is overload-
ed. Exhaust temperature is
high.
Check whether the system
of the compressor is running
normally.