ThermalFlo Addendum
4. Remote On/Off Screen
– Allows the operator to turn the Relay Remote mode On and Off. In
Relay Remote mode, the heat pump is started and stopped by remote relays in an automation
controller. The local Pool and Spa setpoints are still active in this Relay Remote mode.
5. AutoSet On/Off Screen
–
This screen is only shown if the AutoSet mode is enabled
during factory setup
. Allows the operator to turn the AutoSet mode On and Off. AutoSet
mode periodically energizes a filter pump contactor to start a remote filter pump which allows the
heat pump to heat or cool the water as necessary.
6. Time Delay Screen
–
This screen is only shown if the heat pump is waiting due to a pre-
programmed delay.
If the heat pump is waiting on any of the restart, pump start, sensing water
temperature or defrost delays this screen shows how much delay time is left.
7. Defrost Temperature
–
This screen is only shown if the defrost feature is enabled during
operator setup
. If the Defrost feature is enabled this screen will display the temperature of the
compressor suction line. This temperature is used to determine when the heat pump requires
defrosting.
8. Alarm Screen
– If an alarm condition is present it will be displayed on this screen. If no alarms
are present the screen will display ALARM STATUS NONE.
9. Mode Screen
– Displays whether the heat pump is in Heat only, Cool only or Auto mode.
It also displays whether the Pool or Spa set point is active. The active set point can be switched
between Pool and Spa by using the UP and DOWN arrows.
REMOTE
REMOTE IS ON/OFF
AUTOSET
OVERRIDE IS ON/OFF
RESTART / PUMP START /
DEFROST / SENSING
WATER TEMP DELAYS
SUCTION TEMP
ACT = ___
ALARM STATUS
AUTO MODE
POOL/SPA