1

SHURFLO

®

 

LO-FLO 105 SERIES RV PUMPS

INSTALLATION MANUAL

SHURflo lo-flo 105 Series RV pumps are rugged, lightweight, compact and provide the ability to self-prime and run dry. 
Standard features include a pressure demand switch, built in 3/8” hose barb ports, flexible mounting feet, splash proof motor, 
and thermal protector. All with the security that comes with a Ul Recognized Component.

INSTALLATION

SHURflo lo-flo 105 Series RV pumps are self-priming and can be located up to 2.5 

feet above the water level. Horizontal and vertical prime vary depending on the fluid 

viscosity and pump configuration. The pump can be at the same level or below the 

tank.

❚ 

The pump should be located in an area that is dry and properly ventilated to pre-

vent heat build-up.

❚ 

Use 50-mesh strainer minimum at the inlet side of the pump. Use flexible hose on 

inlet.

❚ 

The pump can be mounted in any position. However, if mounting the pump verti-

cally the pump head should be in the down position so that in the event of a leak, 

fluid will not enter the motor.

❚ 

12 Volt pump must be provided with a 5-amp fuse.

❚ 

Recommended wire size is 16 gauge (1.3 mm) or larger wire as determined by volt-

age drop. Negative (-) must be connected to a known ground. Ground wire must be 

the same (gauge/mm) as the positive.

TROUBLESHOOTING

PUMP WILL NOT START

√  for correct voltage (+10%) and 

electrical connections

√  fuse or breaker

√  Pressure switch operation and   

correct voltage at switch

√  Rectifier or motor for open or 

grounded circuit

√  for locked drive assembly

PUMP WILL NOT PRIME 

(No Discharge/Motor Runs)

√  Strainer for debris

√  Inlet/outlet tube severely restricted 

(kinked)

√  Inlet /outlet valves for debris or 

swelling

PUMP WILL NOT SHUT-OFF

√  output line closed and no leaks

√  for air trapped in outlet line or 

pump head

√  for correct voltage to pump

√  Debris in pump Inlet/outlet valves

√  for loose drive assembly or pump 

head screws

√  Pressure switch operation/adjust-

ment

LEAKS FROM PUMP HEAD OR SWITCH

√  for loose screws at switch or pump 

head

√  Switch diaphragm ruptured or 

pinched

√  for punctured diaphragm if fluid is 

present at drain holes

To Faucet

City Water

Check Valve

Alternate Plumbing

for City Water Entry

From Pump

“T” Fitting

RED(+)

PUM P

SWITCH

BLACK(-

)

FUSE

BATTERY

50 Mesh Strainer Required if using SHURFLO P/N 170-06X-00
A 1/2” to 3/8” Barb splicer is required.

Water Tank

Plumbing Systems can vary.

Consult SHURflo for detailed 

information.