14-Slot AdvancedTCA Shelf
Shelf Installation
11596-100/-101/-102/-103
www.a-tca.com / www.schroff.biz
19
R1.1, July 23, 2008
3.9 Initial Operation
Before installing the ATCA boards ensure that there is no transport damage and
the system is fully operational.
Apply power to PEM A and PEM B and watch the boot-up process.
Boot-up process:
1 All of the LEDs on the Shelf Alarm Display, the Shelf Manager, the Fan
Trays an the PEMs turn on, the fans are spinning with full speed
2 The LEDs on the Shelf Alarm Display with exception of the Fan Tray status
LEDs turn off
3 The fans reduce speed up to the initial speed
4 The red LEDs on PEMs, Fan Trays and the Fan Tray status LEDs on Shelf
Alarm Display turn off
5 All blue Hot-Swap LEDs blink
6 All blue Hot-Swap LEDs turn off
7 All Status-OK LEDs are green
The Status LED of the active Shelf Manager is solid green, the Status LED of
the backup Shelf Manager is blinking.