Product Specifications
FG2-6L
FG2-12L
FG2-18L
FG2-24L
Cable length (ft/m)
6 (1.8)
12 (3.7)
18 (5.5)
24 (7.3)
Min. thermal output on a pipe at 40°F/4°C (watts)
30
60
90
120
Min. thermal output on a pipe at 0°F/–18°C (watts)
46
92
138
184
Max. current draw on a pipe at 40°F/4°C (amps)
0.21
0.43
0.64
0.85
Max. current draw on a pipe at 0°F/–18°C (amps)
0.32
0.64
0.96
1.28
General Specifications for all FG2 Products
Maximum cable width (inch/mm)
0.45 (11.4)
Maximum cable thickness (inch/mm)
0.24 (6.1)
Heating cable bus wire gauge (AWG)
16
Voltage rating (Vac)
208–240
Circuit breaker size
15 A max.
Cold lead length (ft/m)
6 (1.83)
Maximum exposure temperature
150°F (65°C)
Minimum installation temperature
5°F (–15°C)
Minimum bend radius (inch/mm)
5/8 (16)
Electrical classification
Nonhazardous areas only
Exposure to chemicals
None