10
Installation (continued)
Do not connect system to a high pressure or city water
system.
Fittings:
Fittings restrict flow; for best efficiency use fewest possible fittings.
Avoid fittings which could cause an air trap.
Electrical
Ground motor before connecting to electrical power
supply. Failure to ground motor can cause severe or
fatal electrical shock hazard.
Do not ground to a gas supply line.
To avoid dangerous or fatal electrical shock, turn
OFF power to motor before working on electrical
connections.
Residual Current Device (RCD) tripping indicates an
electrical problem. If RCD trips and will not reset,
have a qualified electrician inspect and repair
electrical system. Onga recommends that a RCD of
30mA trip current be installed and/or be in
compliance with local regulations.
Exactly match supply voltage to motor nameplate
voltage. Incorrect voltage can cause fire or seriously
damage motor and voids warranty. If in doubt
consult a licensed electrician.
The power supply lead has a type “Y” connector and
if service is required to the power lead, it must be
replaced with the appropriate specialised power lead
assembly. Warranty is void if unauthorised
modifications are made to any component.