Pentair NRG-Temp Скачать руководство пользователя страница 1

NRG-Temp

EN-NRGtemp-IM-EU0309  R0

THERMAL BUILDING SOLUTIONS

210116

Software version 3.2

pentairthermal.com/manuals/

CZ – DA- DE- EN – ES – ET – FI – FR – HU – IT – LT – LV – NL – NO – PL – RU – SV

All manuals and user guides at all-guides.com

all-guides.com

Содержание NRG-Temp

Страница 1: ...p IM EU0309 R0 THERMAL BUILDING SOLUTIONS 210116 Software version 3 2 pentairthermal com manuals CZ DA DE EN ES ET FI FR HU IT LT LV NL NO PL RU SV All manuals and user guides at all guides com a l l...

Страница 2: ...2 82 82 57 33 70 5 70 5 Figure 1 Figure 2 All manuals and user guides at all guides com...

Страница 3: ...3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 14 6 3 Automatic R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 2 0h 3 6 9 12 15 18 2 15 6 3 1 In Comfort Program 15 6 3 2 In Economic Programs EcoH EcoO...

Страница 4: ...t for the floor sensor 24 7 1 8 User Menu 8 Minimum temperature set point for the room sensor 24 7 1 9 User Menu 9 Maximum temperature set point for the room sensor 25 7 2 The Installers or Advanced U...

Страница 5: ...This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervi...

Страница 6: ...rammable Timer Thermostat that is preloaded with 4 programs see Table 1 Program Name Description Symbol Comfort Program In the Comfort Program the NRG Temp is aiming for 1 temperature only called the...

Страница 7: ...od comfort feeling when being present in the room R C EcoH EcoO Stan Booster Temperature Sometimes it can be interesting to give a boost to your underfloor heating The booster function will raise your...

Страница 8: ...o protect the thermostat against draughts e g with a piece of insulation in the conduit outlet 1 5 m Figure 3 If the NRG Temp is mounted in a wall with a rough surface e g bricks use silicon glue to m...

Страница 9: ...on of the thermostat For best control performance position the floor sensor between two heating cables as close as possible to the top floor surface Do not position the floor sensor tip closer than 3...

Страница 10: ...ntegrated suppression device Do not use contactor without interference filter Figure 6 If you connect multiple heating cables you must use a contactor Normally Open with integrated suppression device...

Страница 11: ...he floor sensor must be installed and activated for any installation with T2QuickNet 3 4 2 NRG TEMP WITH THE T2RED T2REFLECTA SELF REGULATING CABLE Self regulating heating cables have an inrush curren...

Страница 12: ...8 21 24 1 I I 7 Figure 9 In this program the NRG Temp is set to the default Comfort temperature of 23 C Use R C EcoHome EcoOffice Standby 0h 3 0h 3 or R C EcoHome EcoOffice Standby to adapt the temper...

Страница 13: ...uare around the function icon 0h 3 6 9 12 15 18 21 24 1 I I 7 0h 3 6 9 12 15 18 21 24 1 I I 7 0h 3 6 9 12 15 18 21 24 1 I I 7 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 1 I I 7 0h 3 6 9 12 15 18...

Страница 14: ...fice Standby 0h 3 6 9 0h 3 6 9 0h 3 6 9 12 15 18 21 24 Reduced Temperature R C EcoHome EcoOffice Standby 0h 3 6 9 0h 3 6 9 Clock R C EcoHome EcoOffice Standby 0h 3 6 9 0h 3 6 9 Program Choice R C EcoH...

Страница 15: ...rn automatically to R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 after the first timer event 6 2 REDUCED TEMPERATURE R C EcoHome EcoOffice Stan...

Страница 16: ...18 21 24 0h 3 6 9 12 15 18 21 24 The Booster is a function used to deviate from the Comfort temperature during a period of 2 hours If you activate the Booster your NRG Temp thermostat will be set for...

Страница 17: ...rogram the Thermostat is set to the default temperature Use R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 21 0h 3 6 9 12 15 18 21 or R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 0h 3 6 9 12 15 to ad...

Страница 18: ...educed R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 33 00 06 12 18 24 02 04 16 14 10 08 20 22 00 06 12 18 24 02 04 16 14 10 08 20 22 00 06 12 1...

Страница 19: ...6 9 12 15 18 21 24 R C EcoHome EcoOffice Standby 0h 3 6 9 12 0h 3 6 9 12 0h 3 6 9 12 15 18 21 24 R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 Figure 16 IMPORTANT Using...

Страница 20: ...and 24 hours with 30 minutes steps Step 3 B Programming the other timeslots Repeat Step 3 A until you have reached the 24 00 hours Step 4 Programming Day 2 to 7 You can either copy the previous day or...

Страница 21: ...Office Standby 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 D Adjustable switching hysteresis R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 0...

Страница 22: ...24 1 I I 7 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 1 I I 7 Figure 22 By using R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 or R C EcoHome EcoOffice Standby 0h...

Страница 23: ...C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 or R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 Possible values 0 to 10 C Factory set valu...

Страница 24: ...to change the temperature in the Comfort R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21 24 Auto R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 21 2...

Страница 25: ...E ROOM SENSOR You can define a maximum temperature set point It is then not possible to change the temperature in the Comfort R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 21 24 0h 3 6 9 12 15 18 21...

Страница 26: ...ruption the thermostat will continue the First Warming function when the power is restored This function can be stopped at any time by setting the installer menu B to OFF Possible values ON OFF Factor...

Страница 27: ...rost Protection menu Fixed set point 7 C Possible values ON OFF Factory set value OFF 7 2 7 USER MENU G PROPORTIONAL REGULATION In room sensing mode the proportional regulation reduces the temperature...

Страница 28: ...2 KEY LOCK FEATURE It is possible to lock the keys of the NRG Temp thermostat 8 2 1 LOCK Press and hold all buttons simultaneously The key symbol R C EcoHome EcoOffice Standby 0h 3 6 9 12 15 18 21 24...

Страница 29: ...one of the temperature sensors the heating output cuts off fail safe and an error code is displayed The floor sensor may be replaced by a new one product reference 1244 002952 In the event of malfunc...

Страница 30: ...lar white RAL 9010 Display LCD with blue backlight Control modes Floor sensor 5 35 C Room sensor 5 40 C Room sensor with floor sensor as a limiter Room temperature control accuracy EN15500 CA 0 7K eu...

Страница 31: ...31 12 APPROVALS AND DECLARATIONS 210116 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 32: ...ICH Tel 0800 297410 Fax 0800 297409 info ptm at pentair com POLSKA Tel 48 22 331 29 50 Fax 48 22 331 29 51 salespl pentair com 7 495 926 18 85 7 495 926 18 86 salesru pentair com SCHWEIZ SUISSE Tel 08...

Отзывы: