background image

4

Part No.

Description

Model Size

Part No.

Description

Model Size

MegaTherm AP, Sizes 500,000-1,825,000

MegaTherm AP, Sizes 500,000-1,825,000

MegaTherm AP, Sizes 500,000-1,825,000

MegaTherm AP, Sizes 500,000-1,825,000

MegaTherm AP, Sizes 500,000-1,825,000

10449521

Hi Tension Lead (orange/red wire
from ignition ctrl to pilot lead) ....... both .. 1670-1825 ..............

ELECTRICAL COMPONENTS (Optional)

E0023300

High Gas Pressure Switch,
Manual Reset ............................... both ....................................

E0023500

Low Gas Pressure Switch
Manual Reset ............................... both ....................................

RE2075100 Low Water Cut Off

Manual Reset, 120 VAC ............... both ....................................

V2000100

Normally Open Vent Valve
24 Volts (System 9, 11) ................ both ....................................

WATER SYSTEM

Code Compliant ASME Tube Assemblies
Built in accordance with the requirements of the ASME Boiler and Pressure
Vessel Code. Individually serialized with H-4 data reports on file as required
by section HG-520.2 and HG-531

Cupronickel tubes with glass-lined headers, ideal for corrosive or
softwater applications (under 7.5 grains hardness) or when hard water
pumping creates higher tube velocities. Suitable for use with swimming
pool heaters.

Indoor Boilers (8 Tubes):
BR098401

Tube Assy ..................................... both .. 500 ..........................

BR098402

Tube Assy ..................................... both .. 600 ..........................

BR098403

Tube Assy ..................................... both .. 715 ..........................

BR098404

Tube Assy ..................................... both .. 850 ..........................

BR098405

Tube Assy ..................................... both .. 1010 ........................

BR098406

Tube Assy ..................................... both .. 1200 ........................

BR098407

Tube Assy ..................................... both .. 1430 ........................

BR098408

Tube Assy ..................................... both .. 670 ..........................

BR098409

Tube Assy ..................................... both .. 1825 ........................

Outdoor Boilers (10 Tubes):
BR001001

Tube Assy ..................................... both .. 500 ..........................

BR001002

Tube Assy ..................................... both .. 600 ..........................

BR001003

Tube Assy ..................................... both .. 715 ..........................

BR001004

Tube Assy ..................................... both .. 850 ..........................

BR001005

Tube Assy ..................................... both .. 1010 ........................

BR001006

Tube Assy ..................................... both .. 1200 ........................

BR001007

Tube Assy ..................................... both .. 1430 ........................

BR001008

Tube Assy ..................................... both .. 1670 ........................

BR001009

Tube Assy ..................................... both .. 1825 ........................

Cupronickel tubes with bronze headers, a non-ferrous solution for the
most demanding systems. Suitable for higher oxygen content hydronic
systems, all volume water applications and excellent for swimming pool
heaters.

Indoor Boilers (8 Tubes):
BR553701

Tube Assy ..................................... both .. 500 ..........................

BR553702

Tube Assy ..................................... both .. 600 ..........................

BR553703

Tube Assy ..................................... both .. 715 ..........................

BR553704

Tube Assy ..................................... both .. 850 ..........................

BR553705

Tube Assy ..................................... both .. 1010 ........................

BR553706

Tube Assy ..................................... both .. 1200 ........................

BR553707

Tube Assy ..................................... both .. 1430 ........................

BR553708

Tube Assy ..................................... both .. 1670 ........................

BR553709

Tube Assy ..................................... both .. 1825 ........................

Outdoor Boilers (10 Tubes):
BR670401

Tube Assy ..................................... both .. 500 ..........................

BR670402

Tube Assy ..................................... both .. 600 ..........................

BR670403

Tube Assy ..................................... both .. 715 ..........................

BR670404

Tube Assy ..................................... both .. 850 ..........................

BR670405

Tube Assy ..................................... both .. 1010 ........................

BR670406

Tube Assy ..................................... both .. 1200 ........................

BR670407

Tube Assy ..................................... both .. 1430 ........................

BR670408

Tube Assy ..................................... both .. 1670 ........................

BR670409

Tube Assy ..................................... both .. 1825 ........................

For copper tube heat exchangers see listing on pages 16-17. It is
recommended to use cupronickle heat exchangers for swimming pool
applications.

10534301

Baffle, HX Front/Rear (indoor) ..... both .. 500 ..........................

10534302

Baffle, HX Front/Rear (indoor) ..... both .. 600 ..........................

10534303

Baffle, HX Front/Rear (indoor) ..... both .. 715 ..........................

10534304

Baffle, HX Front/Rear (indoor) ..... both .. 850 ..........................

10534305

Baffle, HX Front/Rear (indoor) ..... both .. 1010 ........................

10534306

Baffle, HX Front/Rear (indoor) ..... both .. 1200 ........................

10534307

Baffle, HX Front/Rear (indoor) ..... both .. 1430 ........................

10534308

Baffle, HX Front/Rear (indoor) ..... old ..... 1670 ........................

10534309

Baffle, HX Front/Rear (indoor) ..... old ..... 1825 ........................

20020108

Baffle, HX Front/Rear (indoor) ..... new ... 1670 ........................

20020109

Baffle, HX Front/Rear (indoor) ..... new ... 1825 ........................

10534601

Baffle, HX
(500 =7 req;  1825=14 req) .......... both .. 500/1825 ................

10534602

Baffle, HX (14 req) ........................ both .. 600 ..........................

10534603

Baffle, HX (14 req) ........................ both .. 715 ..........................

10534604

Baffle, HX (14 req) ........................ both .. 850 ..........................

10534605

Baffle, HX (14 req) ........................ both .. 1010 ........................

10534606

Baffle, HX (28 req) ........................ both .. 1200 ........................

10534607

Baffle, HX (28 req) ........................ both .. 1430 ........................

10534608

Baffle, HX (28 req) ........................ old ..... 1670 ........................

10534602

Baffle, HX (14 req) ........................ old ..... 1825 ........................

10667702

Baffle, HX (14 req) ........................ new ... 1825 ........................

10667708

Baffle, HX (28 req) ........................ new ... 1670 ........................

10667709

Baffle, HX (14 req) ........................ new ... 1825 ........................

20020101

Baffle, HX Front/Rear
(outdoor) (2 req) ........................... both .. 500 ..........................

20020102

Baffle, HX Front/Rear
(outdoor) (2 req) ........................... both .. 600 ..........................

20020103

Baffle, HX Front/Rear
(outdoor) (2 req) ........................... both .. 715 ..........................

20020104

Baffle, HX Front/Rear
(outdoor) (2 req) ........................... both .. 850 ..........................

20020105

Baffle, HX Front/Rear
(outdoor) (2 req) ........................... both .. 1010 ........................

20020106

Baffle, HX Front/Rear
(outdoor) (2 req) ........................... both .. 1200 ........................

20020107

Baffle, HX Front/Rear
(outdoor) (2 req) ........................... both .. 1430 ........................

20020108

Baffle, HX Front/Rear
(outdoor) (2 req) ........................... both .. 1670 ........................

20020109

Baffle, HX Front/Rear
(outdoor), (2 req) .......................... both .. 1825 ........................

10667701

Baffle, HX (8 tube outdoor)
(500 =qty 7; 1825=14 req) ............ both .. 500 ..........................

10667702

Baffle, HX (8 tube outdoor)
(14 req) ......................................... both .. 600 ..........................

10667703

Baffle, HX (8 tube outdoor)
(14 req) ......................................... both .. 715 ..........................

10667704

Baffle, HX (8 tube outdoor)
(14 req) ......................................... both .. 850 ..........................

10667705

Baffle, HX (8 tube outdoor)
(28 req) ......................................... both .. 1010 ........................

Содержание MegaTherm MT

Страница 1: ...Pentair Commercial Pool Heaters Ordering P N 472645 MegaTherm MT 500 5000 MBTU h PowerMax PM 500 2000 MBTU h...

Страница 2: ...Trademarks and disclaimers PowerMax MegaTherm and the Pentair Commercial Pool and Spa logo are trademarks of Pentair Water Pool and Spa Inc Other trademarks and trade names may be used in this documen...

Страница 3: ...Options 4 Features and Options 5 Special Codes Options 5 Heat Exchangers 5 Table of Contents Prices subject to change call 800 831 7133 for availability and lead times Powermax PM Standard Features 5...

Страница 4: ...w water cutoff manual reset with test button manual firing valve 2nd shutoff valve leak test valve 100 lockout high low gas pressure switches motorized safety valve motorized safety with proof of clos...

Страница 5: ...bes O O O Glass Lined Cast Iron Headers S S S Bronze Headers O N A N A Codes ASME CSD 1 O O O IRI O O O FM O O O Kentucky S S S Minnesota O O O Legend S Standard O Optional SP Standard with CSD 1 spar...

Страница 6: ...DOOR OUTDOOR FUEL N NATURAL P PROPANE PUMP N NORMAL SIZE MBTU h 0 5 0 0 0 7 5 0 1 0 0 0 1 2 5 0 1 5 0 0 1 7 5 0 2 0 0 0 HEAT EXCHANGER B GLASS LINED CAST IRON COPPER BRONZE TRIM Std K BRONZE COPPER P...

Страница 7: ...parate line item Low Water Cut Off Kit No KM000500 KM000500 KM000500 KM000500 KM000500 KM000500 KM000500 factory mounted wired Reversed HX pump mounted Kit No KM000302 KM000302 KM000302 KM000302 KM000...

Страница 8: ...P N 472645 Rev A 05 22 06 Litho in U S A...

Страница 9: ...Sizes 210 000 5 000 000 BTU h P N 472645 Heater Name Model Sizes Doc No MegaTherm Commercial Pool Heater MT 500 1825 472643 MegaTherm Commercial Pool Heater MT 2000 5000 472644 PowerMax Commercial Po...

Страница 10: ...s Unused Parts Parts in new condition with all original packaging will be considered for return within one year of date of purchase from Pentair subject to a 25 restocking charge and recovery of other...

Страница 11: ...Orifice LP Gas 0 4000 ft both L0032800 Orifice LP Gas 4001 8000 ft both L0032700 Orifice LP Gas 8001 10000 ft both V0004200 Gas Valve Manual 1 Nat LP 1010 1200 both 500 715 V0004300 Gas Valve Manual...

Страница 12: ...3707 Tube Assy both 1430 BR553708 Tube Assy both 1670 BR553709 Tube Assy both 1825 Outdoor Boilers 10 Tubes BR670401 Tube Assy both 500 BR670402 Tube Assy both 600 BR670403 Tube Assy both 715 BR670404...

Страница 13: ...0305 Impeller 4 85 dia Armstrong 1050 1825 JACKET AND COMBUSTION CHAMBER COMPONENTS See listings in MegaTherm Models HH PH VW PW and IW for common components COMPLETE TILE ASSEMBLIES See Tile Assembly...

Страница 14: ...y NLA use K20031909 20039600 Complete Pilot Assy Spark Ignition LP NLA use K20039600 E0013000 Flow Switch outdoor NLA E0066200 Dual Aquastat Hi Limit w Manual Reset NLA use KE0066200 E0086100 Transfor...

Страница 15: ...023300 High Gas Pressure Switch E0023500 Low Gas Pressure Switch V2013800 Valve Manual V2013900 Valve Manual V2003100 Valve Ball Lubricated V2003200 Valve Ball Lubricated 1 1 2 Jomar V2003300 Valve Ba...

Страница 16: ...0 20003202 Heat Shield Support 2450I 2200E 20003203 Heat Shield Support 3050I 2800E 20003204 Heat Shield Support 3500I 3200E 20003205 Heat Shield Support 4050I 3600E 20003206 Heat Shield Support 4500I...

Страница 17: ...3600E BR010806 Tube Assy 4500I 4000E BR010807 Tube Assy 5000I 4500E Copper tubes w bronze headers a non ferrous solution for systems w higher oxygen content Especially suited for volume water applica...

Страница 18: ...q 5000I 4500E 20006401 Front Rear Closure 2 req 2000 20006402 Front Rear Closure 2 req 2450I 2200E 20006403 Front Rear Closure 2 req 3050I 2800E 20006404 Front Rear Closure 2 req 3500I 3200E 20006405...

Страница 19: ...Lower Front Closure Assy 20016205 Lower Front Closure Assy 20016206 Lower Front Closure Assy 20016207 Lower Front Closure Assy 20017202 Upper Wind Baffle Front Rear qty 2 20017203 Upper Wind Baffle F...

Страница 20: ...000E 20018307 Screen Retaining Strap 5000I 4500E 20018400 Front Stiffener all 20018602 Upper Front Rear Mesh Screen 2450I 2200E 20018603 Upper Front Rear Mesh Screen 3050I 2800E 20018604 Upper Front R...

Страница 21: ...9001 10000 L2008000 L2005400 31 43 OUTDOOR GAS MODEL SIZE INDOOR OUTDOOR INDOOR MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT Gas Orifice Size Chart Ga...

Страница 22: ...emblies MT ile Assemblies MT ile Assemblies MT ile Assemblies MT AP After April 1999 Sizes 500 000 1 825 000 Cement Tile When ordering tiles Assembly number is for all tiles Part numbers shown at fron...

Страница 23: ...lies MT ile Assemblies MT ile Assemblies MT ile Assemblies MT AP Units Before April 1999 Sizes 500 000 1 825 000 Pyro Tile When ordering tiles Assembly number is for all tiles Part numbers shown at fr...

Страница 24: ...16 Tile Assemblies MT Sizes 2 000 000 5 000 000 Pyro Tile I Indoor E Outdoor...

Страница 25: ...15C2002 Divider Chamber Front 1250 1500 20C2002 Divider Chamber Front 1750 2000 5C2005 Door Comb Air Chamber Access 1 or 2 used 500 2000 5C2007 Exhaust Plenum 500 750 10C2007 Exhaust Plenum 1000 20C2...

Страница 26: ...ressure 500 2000 10364201 Pump Adapter bronze 500 2000 10364200 Pump Adapter glass lined cast iron 500 2000 10483300 Pump Housing bronze 500 2000 R10261501 Pump Housing glass lined cast iron 500 2000...

Страница 27: ...Size 5C3002 Plate Cover Filter 500 1000 15C3002 Plate Cover Filter 1250 2000 5C3502 Plate Cover Wiring 500 2000 5C3304 Plate Gas Pipe Seal 500 7C3304 Plate Gas Pipe Seal 750 10C3304 Plate Gas Pipe Sea...

Страница 28: ...Trademarks and disclaimers PowerMax MegaTherm and the Pentair Commercial Pool and Spa logo are trademarks of Pentair Water Pool and Spa Inc Other trademarks and trade names may be used in this documen...

Отзывы: