Pentair Cleanload chemical eductors are designed to mix fluids and dry chemicals in a self-contained system. The inline 

eduction system allows the operator to mix chemicals quickly and safely. The Cleanload operates by receiving a fluid into 

the eductor where a fluid or dry chemical is mixed in. The mixture is then transferred into a holding tank to be used for 

spraying crops. Construction features a polypropylene venturi eductor and polyethylene hopper tank and FKM gaskets.

Intended Uses

The Cleanload is designed and constructed for incorporation into a large variety of applications that require the mixing 

of liquid and dry chemicals. All other uses are to be considered misuses unless approved by the manufacturer. The 

Cleanload can be used in a wide variety of conditions including:

• Fluid temperatures ranging from 1 to 49°C (34 to 120°F).

• The Cleanload must only be used in outdoor or well-ventilated areas.

Purpose of Manual

Hypro has provided this manual to provide instructions and requirements that must be met when installing, using and 

maintaining the product(s) included in this document.

If the product is sold, the seller must pass this manual on to the new owner.

The following special attention notices are used to notify and advise the user of this product of procedures that may be 

dangerous to the user or result in damage to the product.

ATTENTION

Attention is used to notify of installation, operation, or maintenance information that is important but not safety related.

This symbol is used to denote the presence of an electrical hazard that will result in personal injury, death or property 

damage.

This symbol is used to denote the presence of a hazard that will result in personal injury, death or property damage.

California Proposition 65 Warning 

-- This product and related accessories contain chemicals known to the

State of California to cause cancer, birth defects or other reproductive harm.

Misuses

Hypro Cleanload are designed to operate effectively within the pressure and environmental ranges. Going outside of 

these ranges will void the warranty and could cause damage to property, serious injury or death. 

•  DO NOT use the Cleanload in a potentially explosive environment.

•  DO NOT use the Cleanload without the tank lid securely attached.

•  DO NOT operate the Cleanload with missing, damaged, or leaking parts. Inspect for damaged parts prior to 

each use.

•  DO NOT use the Cleanload in drinking water or any other system producing products for human 

consumption.

•  DO NOT use the Cleanload without the proper personal protection equipment.

•  DO NOT use the Cleanload if it is not properly secured into position.

•  DO NOT exceed the maximum pressure when using the Cleanload.

•  ***DO NOT use the Cleanload in wind exceeding 10 MPH.***

• 

DO NOT move the Cleanload when filled with fluid.

- 3 -

Содержание HYPRO Cleanload Max 3378 Series

Страница 1: ...2 26 2016 PART WEIGHT PDU Ppk Cpk MIN CHARACTERISTIC TYPE SYM 1 67 1 33 CRITICAL SIGNIFICANT PART VOLUME 375 Fifth Avenue NW New Brighton MN 55112 651 766 6300 APPROVED BY DWG BY CHECKED BY DATE DATE DATE 6 03 2016 MGC 6 03 2016 MGC 1 4 A THIRD ANGLE PROJECTION DRAWING BASED ON ASME Y14 5M 1994 PART DESCRIPTION SCALE REV PART NUMBER THIS DRAWING IS THE PROPERTY OF PENTAIR LTD AND WITHOUT WRITTEN A...

Страница 2: ...ansport and Intermediate Storage 5 Assembly and Installation 5 Assembly 5 Installation 5 Control Systems 6 Commissioning Start Up Operation Shutdown 7 Information 7 Start Up Operation Shutdown 7 Maintenance and Servicing 8 Information 8 Disposal 8 Cleaning 8 Maintenance Routine Servicing and Inspection 8 Troubleshooting 9 Replacement Parts 10 Warranty 12 ...

Страница 3: ...ocedures that may be dangerous to the user or result in damage to the product ATTENTION Attention is used to notify of installation operation or maintenance information that is important but not safety related This symbol is used to denote the presence of an electrical hazard that will result in personal injury death or property damage This symbol is used to denote the presence of a hazard that wi...

Страница 4: ...2 69 137 26 4 1 3 40 164 29 5 5 3 71 186 39 6 9 4 09 206 38 C S I 1133 44 6 132 5 2 474 18 7 831 32 7 885 34 9 82 7 3 3 130 5 1 254 10 0 508 20 0 790 31 1 REVISIONS REV ECN REVISION DESCRIPTION CHKD DATE A 14859 INITIAL RELEASE PDU 6 03 2016 HYPRO D L REV E 2 26 2016 PART WEIGHT PDU Ppk Cpk MIN CHARACTERISTIC TYPE SYM 1 67 1 33 CRITICAL SIGNIFICANT PART VOLUME 375 Fifth Avenue NW New Brighton MN 5...

Страница 5: ... bar Eduction Rate L sec Flow Rate L min 1 4 1 85 92 29 2 7 2 99 136 77 4 1 3 52 162 28 5 5 3 67 185 94 6 9 3 97 205 96 3378 1640 3BYP 3378 1660 3BYP Input Pressure bar Eduction Rate L sec Flow Rate L min 1 4 2 11 226 10 2 7 3 10 295 34 4 1 3 41 349 13 5 5 3 48 394 06 6 9 3 44 435 02 3378 1140 3378 1160 Input Pressure PSI Eduction Rate gal sec Flow Rate gal min 20 0 57 27 06 40 0 86 38 09 60 0 85 ...

Страница 6: ...are mounting the Cleanload to identify suitable plumbing connections and mounting locations Securely mount the Cleanload in a place that is out of the way of moving equipment and allow for safe routing of plumbing Ensure that the ball valve handles are easily accessible and have enough clearance to complete their full range of motion Connect inlet and outlet hoses minimum 2 51mm internal diameter ...

Страница 7: ...ng subsections of the Assembly and Installation section of this manual Commissioning Start Up Operation Shutdown Before attempting to operate your Cleanload the following must be understood and followed to ensure safe operation Information Read the operating instructions to follow completely before using the Cleanload CLEAN WATER BULK CHEMICAL TO TANK 3378 WITH 3376 ASSEMBLY SF1100 Mini Bulk Chem ...

Страница 8: ...the hopper valve red handle is open to allow flow from the enclosure If the backup persists immediately close the Cyclo Rinse blue handle and the hopper valve red handle and shut off the pump Review outlet plumbing to minimize restrictions or blockages Start up Operation Shut Down 1 Turn on the pump to generate clean water flow 2 Open the tank hopper red handle and the Cyclo Rinse valve blue handl...

Страница 9: ... are free of any chemical buildup or residue both inside and out Failing to properly clean the system could lead to reduced performance and component life Be sure to thoroughly clean the eductor ball valves and internal components in the hopper Cycle the ball valves open and close during rinsing to ensure they are clean Maintenance Routine Servicing and Inspection PREVENTATIVE MAINTENANCE CHECK LI...

Страница 10: ...hopper outlet with the hopper valve open observe the liquid jet should be centered and straight If it is off center or if it is dispersed flush the system with clean water and remove the fittings from both sides of the eductor Using a soft tool wood or plastic and taking care to not deform the orifice clear the blockage by pushing it back out toward the inlet side of the fitting A blocked eductor ...

Страница 11: ...040R EDUCTOR 16mm FOR MODELS 3378 1640 3378 1660 20 1 3430 0944 KIT TUBING 40 GALLON 20 1 3430 0945 KIT TUBING 60 GALLON 21 1 7250 5000 TANK VALVE 22A 1 9951 2300UF BALL VALVE 2 FOR 2BYP MODELS 22B 1 9951 2300UF BALL VALVE 3 FOR 3BYP MODELS 23 1 PC1 2F 36075 NOZZLE ProClean CONTAINER RINSE 24 1 PV1 2F1 2M MA ProClean CONTAINER RINSE 25 1 TL16 0006 LID KIT 26 2 UF200P PLUG 2 INCH 27 BGUFC0200 S CLA...

Страница 12: ...eration Hypro reserves the right to request a Material Safety Data Sheet from the returnee for any pump product it deems necessary Hypro reserves the right to disposition as scrap products returned which contain unknown fluids Hypro reserves the right to charge the returnee for any and all costs incurred for chemical testing and proper disposal of components containing unknown fluids Hypro request...

Отзывы: