NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible 

party who maintains the system.

TG-PRO SYSTEM

COMPLETE GRINDER

PACKAGE OFFERING

INSTALLATION AND SERVICE MANUAL

For use with Hydromatic grinder pumps: HPG200, HPGR200 and HPD200 (shown on cover).

Item # E-03-434  |  Part # 5625-434-1  |  © 2012 Pentair Pump Group, Inc.  |  10/31/12 

Содержание Hydromatic TG-Pro System

Страница 1: ...ip ment or to the responsible party who maintains the system TG PRO SYSTEM COMPLETE GRINDER PACKAGE OFFERING INSTALLATION AND SERVICE MANUAL For use with Hydromatic grinder pumps HPG200 HPGR200 and HP...

Страница 2: ...Only qualified personnel may install this system NFPA 70 National Electric Code NEC or local codes must be followed System must be properly grounded according to NEC Biohazard risk Once the wastewater...

Страница 3: ...lt in structural failure or serious leaks Step 2 Lubricate inside lip of inlet grommet with pipe soap Clean outer end of influent pipe and push pipe through grommet Ensure pipe does not protrude insid...

Страница 4: ...or electrical connections made to the basin Unpacking Pump Remove pump from carton When unpacking unit check for concealed damage Claims for damage must be made at the receiving end through the deliv...

Страница 5: ...ion Box Systems Step 1 Ensure power source is off or dis con nect ed Step 2 Pushpumppower sealfailure heat sensor and float cords through cord grips in the junction box and tighten To prevent corrosio...

Страница 6: ...onduits and cables entering the panel must be sealed off For single phase pumps Check panel wiring to ensure white black and red pump leads are connected according to the schematic and panel wire labe...

Страница 7: ...ner retrace control float wiring panel Step 7 Ensure H O A switch is set to Auto before placing system into service Below is a list of common problems and possible solutions Refer to the pump and pane...

Страница 8: ...te black and red pump power leads must be connected correctly to panel Overload trips is manually reset and then trips off again 1 Cutters may be clogged It is possible that the pump stalled during op...

Страница 9: ...20 Cross 1 1 4 SST 1 18a 05004A122 Bushing 1 1 4 x 1 2 PVC 1 18b 149850001 Valve Relief 1 19 148790001 Valve Anti Siphon 1 20 05004A114 Bushing 1 1 4 x 3 4 PVC 1 21 05008A059 Nipple 3 4 Close PVC 1 22...

Страница 10: ...ef 1 19 148790001 Valve Anti Siphon 1 20 05004A114 Bushing 1 1 4 x 3 4 PVC 1 21 05008A059 Nipple 3 4 Close PVC 1 22 24335A001 4 Inlet Grommet 1 23a 2397A012 Rope Liftout 15 1 23b 23828A005 Chain Lifto...

Страница 11: ...004A122 Bushing 1 1 4 x 1 2 PVC 2 18b 149850001 Valve Relief 2 19 148790001 Valve Anti Siphon 2 20 05004A114 Bushing 1 1 4 x 3 4 PVC 2 21 05008A059 Nipple 3 4 Close PVC 2 22 24335A001 4 Inlet Grommet...

Страница 12: ...and from the factory or an authorized Pentair Hydromatic service facility This limited warranty will not apply a to defects or malfunctions resulting from failure to properly install operate or maint...