SETTING TIME OF DAY AND 
INITIATING A MANUAL 
REGENERATION

Setting the Time of Day

1.  Press and hold either the Up or Down button for 

two seconds.

2.  Press the Shift button to select the digit you want to 

modify.

3.  Press the Up or Down button to adjust the value.
4.  Press the Extra Cycle button to return to the normal 

display screen, or wait for a five second timeout.

Queueing a Regeneration

1.  Press the Extra Cycle button. The Display Screen 

will show “RGQ” as the valve status, indicating that 

a regeneration is scheduled..

2.  To cancel a queued regeneration, press the Extra  

Cycle button.

Regenerating Immediately

Press and hold the Extra Cycle button for five seconds.

Figure 1 Up and Down Buttons

Figure 2 Shift Button

Figure 3  Extra Cycle Button

WARNING:

 Before entering User Programming, 

please contact your local water treatment 

professional. For complete programming options, 

refer to Master Programming Flow Chart.

Enter User Mode

•  Press and hold the Up or Down buttons for 5 

seconds.

Set Language Option

•  Press Up or Down to select language.
•  Press the Extra Cycle button to proceed to the 

next step.

 Set Feed Water Hardness

Press the Shift, Up, and Down buttons to move the 

cursor and change the value of the numbers.

Press the Extra Cycle button to proceed to the next 

step.

NOTE: Only displayed when a metered option is 

chosen under System Type.

Set Regeneration Day Override

•  To turn On and set the days, press the Down 

button.

•  Press the Shift, Up, and Down buttons to move 

the cursor and change the value of the numbers.

•  Press the Extra Cycle button to proceed to the 

next step.

Regeneration Time

•  Press the Shift, Up, and Down buttons to move 

the cursor and change the value of the numbers.

•  Press the Extra Cycle button to end user 

programming mode.

USER PROGRAMMING

Figure 4 Select Language Screen

Figure 5 Feed Water Hardness Screen

Figure 6 Regeneration Day Override Screen

Figure 7 Regeneration Time Screen

4 • 

Fleck

 NXT Owner’s Manual

Содержание FLECK NXT

Страница 1: ...FLECK NXT OWNER S MANUAL waterpurification pentair com...

Страница 2: ...ing system WARNING The power outlet must be grounded and always on If it is necessary to disconnect power unplug the AC adapter from its power source WARNING Only fill the brine tank with salt designe...

Страница 3: ...digit selecting LED Status indicator Blue In service Flashing Blue Regeneration Queued Green Regeneration Flashing Green Standby Red Error with codes System Number Valve Address Valve State Flow Indi...

Страница 4: ...g options refer to Master Programming Flow Chart Enter User Mode Press and hold the Up or Down buttons for 5 seconds Set Language Option Press Up or Down to select language Press the Extra Cycle butto...

Страница 5: ...ic Bypass Valve To return the conditioner system to regular service turn both of the knobs on the bypass counter clockwise back to their original positions Manual Bypass This type of bypass system is...

Страница 6: ...queue a regeneration Once power is restored the control will initiate a regeneration cycle the next time that the Time of Day equals the programmed regeneration time Typically this means that the val...

Страница 7: ...ssage Displayed Correction Flashing time Power outage Press any button to clear flashing display See SETTING TIME OF DAY AND INITIATING A MANUAL REGENERATION to reset time if needed See CONTROL OPERAT...

Страница 8: ...Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal opportunity employer 44052 REV A JA16 2016...

Отзывы: