Protection rating
IP 22
Power supply
100 to 240 VAC, 50/60 Hz, 0.8 A, Class II
Transient overvoltages
Within the limits of category II
Pollution Degree
3
Temporary overvoltages must be limited in duration and in frequency.
Environmental conditions
• Indoor use only;
• temperature from 5°C to 40°C;
• maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50%
relative humidity at 40°C;
• mains supply voltage fluctuations up to ±10% of the nominal voltage.
3.2
Performance flow rate characteristics
The graph shows the pressure drop created by the valve itself at different flow rates. It allows
predetermining the maximum flow rate going through the valve depending on the system settings
(inlet pressure etc). It also allows to determine the valve pressure drop at a given flow rate, and
therefore to evaluate the system pressure drop vs flow rate.
FLOW RATE VS PRESSURE DROP
Service
Backwash
Flow rate [m³/h]
Pressure drop [bar]