4.2.3. Resin exchange capacity and capacity of the unit
The resin exchange capacity and capacity of the unit are two different things that should not be
confused. The resin exchange capacity is the amount of Ca
2+
and Mg
2+
that can be retained by 1 litre
of resin, which will depend on the resin type and salt dosage, whereas the capacity of the unit is the
capacity of the system, which will depend on the volume of resin and resin exchange capacity.
Knowing the required volume of resin, you can determine the exchange capacity of the unit. The
capacity of the unit can be expressed in different ways:
•
the mass capacity, which corresponds to the weight in equivalent CaCO
3
that can be fixed on the
resin, expressed in kg as CaCO
3
;
•
the volume capacity, which represents the maximum amount of water that can be treated
between two regenerations. This last capacity takes into account the hardness of the water to be
treated and is expressed in m
3
or litres;
•
the combined capacity, which represents the volume of water that could be treated between two
regenerations if the inlet hardness is 1 °f or °dH. This capacity is expressed in °f.m
3
or °dH.m
3
.
The resin exchange capacity will depend on the amount of salt to be injected into the resin bed during
the regeneration. This amount of salt is given in grams per litre of resin. The next table is showing the
resin exchange capacity in function of the amount of salt for a system with standard efficiency
regeneration.
Resin exchange capacity as a function of the salt dosage:
Salt amount
[g/L
resin
]
Corresponding resin exchange
capacity in [g/L
resin
] as CaCO
3
°f.m
3
[per L
resin
]
°dH.m
3
[per L
resin
]
50
29.9
2.99
1.67
60
34
3.4
1.9
70
37.5
3.75
2.09
80
40.6
4.06
2.27
90
43.4
4.34
2.42
100
45.9
4.59
2.56
110
48.2
4.82
2.69
120
50.2
5.02
2.8
130
52.1
5.21
2.91
140
53.8
5.38
3.01
150
55.5
5.55
3.1
Содержание Fleck 4600-MECH
Страница 1: ...FLECK 4600 MECH INSTALLER MANUAL WATER PURIFICATION ...
Страница 16: ...Installer Manual Fleck 4600 MECH Description 16 88 Ref MKT IM 027 B 01 06 2018 3 2 Outline drawing ...
Страница 59: ...Installer Manual Fleck 4600 MECH Maintenance Ref MKT IM 027 B 01 06 2018 59 88 ...
Страница 61: ...Installer Manual Fleck 4600 MECH Maintenance Ref MKT IM 027 B 01 06 2018 61 88 ...
Страница 74: ...Installer Manual Fleck 4600 MECH Spare parts 74 88 Ref MKT IM 027 B 01 06 2018 11 3 Valve parts list ...
Страница 76: ...Installer Manual Fleck 4600 MECH Spare parts 76 88 Ref MKT IM 027 B 01 06 2018 11 4 Meters parts list ...
Страница 87: ...Installer Manual Fleck 4600 MECH Disposal Ref MKT IM 027 B 01 06 2018 87 88 PAGE INTENTIONALLY LEFT BLANK ...
Страница 88: ...www pentairaquaeurope com ...