Installer manual Fleck 3150 NXT/NXT2 - System sizing
34 / 182
Ref. MKT-IM-010 / C - 18.10.2019
V
WB
= D
Salt
x BV / S
sol
with:
V
WB
: Volume of water to be refill to prepare the
brine [L]
D
Salt
: Salt dosage per liter of resin [g/L]
BV: Bed volume [L]
S
sol
: 360g/L - Solubility of salt per liter of water
Info
When calculating the time required to draw the brine, take into account that the volume
of brine [V
brine
] will be 1.125 bigger than the volume of water refilled.
4.3
Salt amount definition
4.4
1800 Injector flow rates
The following tables and graphics represent the injectors flow rate as a function of the
inlet pressure for the different injector sizes.
INJECTOR 5
Total
Rinse
Draw
Flow rate [l/min]
Inlet pressure [bar]