Job Number: __________________
Model Number: ________________
Water Hardness: ___________________ ppm or gpg
Capacity Per Unit: ______________
Mineral Tank Size: ___________ Diameter: ___________ Height:
Salt Setting per Regeneration: _____________________________________________
1. Type of Timer:
A. 7 Day or 12 Day
B. Meter Initiated
2. Downfl ow:
Upfl ow
Upfl ow Variable
3. Meter Size:
A. 3/4” Std Range (125 - 2,100 gallon setting)
B. 3/4” Ext Range (625 - 10,625 gallon setting)
C. 1” Std Range (310 - 5,270 gallon setting)
D. 1” Ext Range (1,150 - 26,350 gallon setting)
E. 1-1/2” Std Range (625 - 10,625 gallon setting)
F.
1-1/2” Ext Range (3,125 - 53,125 gallon setting)
G. 2” Std Range (1,250 - 21,250 gallon setting)
H. 2” Ext Range (6,250 - 106,250 gallon setting)
I.
3” Std Range (3,750 - 63,750 gallon setting)
J.
3” Ext Range (18,750 - 318,750 gallon setting)
K. Electronic________ Pulse Count ________ Meter Size
4. System Type:
A. System #4: 1 Tank, 1 Meter, Immediate, or Delayed Regeneration
B. System #4: Time Clock
C. System #4: Twin Tank
D. System #5: 2-5 Tanks, 2 Meters, Interlock
E. System #6: 2-5 Tanks, 1 Meter, Series Regeneration
F.
System #7: 2-5 Tanks, 1 Meter, Alternating
G. System #9: Electronic Only, 2-4 Tanks, Meter per Valve, Alternating
H. System #14: Electronic Only, 2-4 Tanks, Meter per Valve. Brings units on and offl ine based on fl ow.
5. Timer Program Settings:
A. Backwash: ______________________ Minutes
B. Brine and Slow Rinse: _____________ Minutes
C. Rapid Rinse: ____________________ Minutes
D. Brine Tank Refi ll: _________________ Minutes
E. Pause Time: ____________________ Minutes
F.
Second Backwash: _______________ Minutes
6. Drain Line Flow Control:
____________ gpm
7. Brine Line Flow Controller:
__________________ gpm
8. Injector Size#:
_____________________
9. Piston Type:
A. Hard Water Bypass
B. No Hard Water Bypass
Job Specifi cation Sheet
Содержание Fleck 2510 ECONOMINDER
Страница 9: ...Page 9 Notes...
Страница 10: ...Page 10 3200 Timer Assembly For Service Assembly Numbers See the Back of this Manual 61502 3200_REVA...
Страница 12: ...Page 12 3210 Timer Assembly For Service Assembly Numbers See the Back of this Manual 61502 3210_REVA...
Страница 14: ...Page 14 Powerhead Assembly Designer For Service Assembly Numbers See the Back of this Manual 61501_2510REVB...
Страница 16: ...Page 16 For Service Assembly Numbers See the Back of this Manual Powerhead Assembly Environmental Page 16...
Страница 19: ...Page 19 Notes...
Страница 35: ...Page 35 Flow Data Injector Draw Rates...
Страница 36: ...Page 36 Wiring Diagram...
Страница 38: ...Page 38 Notes...
Страница 39: ...Page 39 Notes...
Страница 40: ...P N 40097 Rev J 1 09...