ETi 400 High Efficiency Pool and Spa Heater Installation and User’s Guide
Rev. A 9/2016
48
Section 3: Troubleshooting
NO
NO
Reset power to Heater and
retry. Heater should fire.
Does the Digital
Temperature Display show
Error Code “E05” or “E06”?
Heater starts and runs OK,
but temperature of exhaust
climbs to 170°F (77°C)
in 3-5 minutes.
Heater starts after several
tries, exhaust temperature
stays below 150°F (65.5°C)
OR
Heater doesn’t start at all
(exhaust stays cold).
Check pressure and volume
of fuel supply
Check the J5 and J8
connectors for corrosion/
looseness on the male
pins.
Check continuity in wiring
harness between Control
Board and Probe.
Continuity OK?
Disconnect the sensor and
check continuity across its
terminals. Resistance
should see:
= open circuit
0 = shorted
Does sensor check OK?
Clean/tighten pins as
needed.
Reset power to Heater
and retry. Heater should
fire.
NOT OK
NO
NO
NO
NO
NO
SFS on
Replace Stack Flue Sensor
Correct Fuel Supply, reset
Heater and retry. Heater
should fire correctly.
Repeat checks on fuel
supply, Thermal Regulator,
check for correct orifices,
etc.
DONE
YES
YES
YES
YES
NO
YES
NO
OK
YES
Correct problem; Heater should
fire.
Check Heat Exchanger
Coil for leaks, liming, soot,
or low flow.
DONE
Replace Heater Control Panel.
Replace Heater Control Board.
Reset power to Heater and
retry. Heater should fire.
Reset power to Heater and
retry. Heater should fire.
DONE
NO
YES
YES
DONE
NO
Diagnostic LEDs: PS, HLS, TF, IGN, AFS, AG1, AG2, FS
Heater should fire on call for
heat. Re-verify that water flow
is above minimum require-
ment.
Minimum Flow Requirements
Model Flow (gpm)
minimum.
ETi 400 40
Temperature
rise (˚F)
30 +/- 5 ˚F
Check the temperature at the
water outlet plumbing from the
tridicator and subtract the water
inlet temperature on the LED.
The difference is the
Temperature Rise (˚F)
.
YES
Resistance Table
T (˚C) -
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Rn (Ohm) *
27396
22140
17999
14716
12099
10000
8308
6936
5819
4904
4151
3529
3012
2582
2221
1918
1663
1446
1262
1105
970
See Resistance Table on right.
Note: (*) +/- 3%