LOCATION AND MOUNTING
1. Hoffman electric heaters should be centered as low as possible in the enclosure for
optimum heat distribution.
2. It is recommended that the heater be installed on a non-combustible metal panel for
optimum performance. It may, however, be mounted on any metal surface.
WARNING: Heaters must not be installed on wood or other combustible surfaces.
3. The heater should be mounted in a vertical position with the terminal block at the
bottom and the air outlet openings at the top as shown.
4. The recommended clearances shown by the shadowed area indicates the space that
should be kept free of components for safe operation of the heater.
WARNING: Heat sensitive components must not be placed above the heater discharge
area.
5. Four 10−32 UNF, self−tapping screws are included for installation.
Vertical Surface Mounting
Optional Horizontal Surface Mounting
Watts
X
D
E
DAH1001A, DAH1002A
100
4
5.00 (127 mm)
3.25 (83 mm)
DAH2001A, DAH2002A
200
6
DAH4001B, DAH4002B
400
6
7.00 (178 mm)
3.50 (89 mm)
DAH8001B, DAH8002B
800
8
DAH13001C, DAH13002C
1300
8
© 2012 Pentair Technical Products
- 3 -
PH 763 422 2211 • hoffmanonline.com
87565511