Pentair C Series Скачать руководство пользователя страница 3

C SERIES

®

 Bronze Commercial Pump Installation Guide

IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS

 

When installing and using this electrical equipment, basic safety 

precautions should always be followed, include the following:

RISK OF ELECTRICAL SHOCK 

(For all permanently 

installed units intended for use on 15 or 20 ampere, 125 

through 240 volt, single phase branch circuits). Connect only to a branch 

circuit protected by a ground-fault circuit-interrupter (GFCI). Contact a 

qualified electrician if you cannot verify that the circuit is protected by a GFCI. 
This unit must be connected only to a supply circuit that is protected by a 

ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by 

the installer and should be tested on a  routine basis. To test the GFCI, push 

the test button. The GFCI should interrupt power. Push the reset button. 

Power should be restored.  If the GFCI fails to operate in this manner, the 

GFCI is  defective. If the GFCI interrupts power to the pump without the test 

button being pushed, a ground current is flowing, indicating the possibility 

of an electric shock. Do not use this pump. Disconnect the pump and have 

the problem corrected by a qualified service representative before using.

This pump is for use with permanent swimming pools 

and may also be used with hot tubs and spas if so 

marked. Do not use with storable pools. A permanently-installed pool is 

constructed in or on the ground or in a building such that it cannot be 

readily disassembled for storage. A storable pool is constructed so that it is 

capable of being readily disassembled for storage and 

reassembled to its original integrity.

General Warnings

•  Never open the inside of the drive motor enclosure. There is a 

capacitor bank that holds a 230 VAC charge even when there is no 

power to the unit.

•  The pump is not submersible.

•  The pump is capable of high flow rates; use caution when installing 

and programming to limit pumps performance potential with old or 

questionable equipment.

•  Code requirements for electrical connection differ from country to 

country, state to state, as well as local municipalities. Install equipment 

in accordance with the National Electrical Code and all applicable 

local codes and ordinances.

•  Before servicing the pump; switch OFF power to the pump by 

disconnecting the main circuit to the pump.

•  This appliance is not intended for use by persons (including children) of 

reduced physical, sensory or mental capabilities, or lack of experience 

and knowledge, unless they have been given supervision or instruction 

concerning the use of the appliance by a person responsible for their 

safety.

FAILURE TO FOLLOW ALL INSTRUCTIONS AND 

WARNINGS CAN RESULT IN SERIOUS BODILY 

INJURY OR DEATH. 

THIS PUMP SHOULD BE INSTALLED AND 

SERVICED ONLY BY A QUALIFIED POOL SERVICE PROFESSIONAL. 

INSTALLERS, POOL OPERATORS AND OWNERS MUST READ THESE 

WARNINGS AND ALL INSTRUCTIONS IN THE OWNER’S MANUAL 

BEFORE USING THIS PUMP. THESE WARNINGS AND THE OWNER’S 

MANUAL MUST BE LEFT WITH THE POOL OWNER.

SUCTION ENTRAPMENT HAZARD: STAY OFF 

THE MAIN DRAIN AND AWAY FROM ALL SUCTION 

OUTLETS!

THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE 

POOL OR SPA WHEN COVERS ARE MISSING, CRACKED OR BROKEN 

CAN RESULT IN BODY OR LIMB ENTRAPMENT, HAIR ENTANGLE-

MENT, BODY ENTRAPMENT, EVISCERATION AND/OR DEATH.  
The suction at a drain or outlet can cause:

Limb Entrapment:

  When a limb is sucked or inserted into an opening 

resulting in a mechanical bind or swelling. This hazard is present when 

a drain cover is missing, broken, loose, cracked or not properly secured.

Hair Entanglement:

 

When the hair tangles or knots in the drain cover, 

trapping the swimmer underwater.  This hazard is present when the flow 

rating of the cover is too small for the pump or pumps.

Body Entrapment: 

When a portion of the body is held against the drain 

cover trapping the swimmer underwater.  This hazard is present when the 

drain cover is missing, broken or the cover flow rating is not high enough 

for the pump or pumps.

Evisceration/Disembowelment:

 

When a person sits on an open pool 

(particularly a child wading pool) or spa outlet and suction is applied directly 

to the intestines, causing severe intestinal damage.  This hazard is present 

when the drain cover is missing, loose, cracked, or not properly secured.

F

THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES 

A STRONG VACUUM AT THE MAIN DRAIN AT THE BOTTOM OF THE 

BODY OF WATER. THIS SUCTION IS SO STRONG THAT IT CAN TRAP 

ADULTS OR CHILDREN UNDER WATER IF THEY COME IN CLOSE 

PROXIMITY TO A DRAIN OR A LOOSE OR BROKEN DRAIN COVER 

OR GRATE.

This guide provides installation and operation instructions for this product. 

Consult Pentair with any questions regarding this equipment. 

Attention Installer: 

This guide contains important information about the 

installation, operation and safe use of this product. This information should 

be given to the owner and/or operator of this equipment after installation 

or left on or near the pump. 

Attention User: 

This manual contains important information that will help 

you in operating and maintaining this product. Please retain it for future 

reference.

This is the safety alert symbol. When you see this 

symbol on your system or in this manual, look for 

one of the following signal words and be alert to the 

potential for personal injury.
Warns about hazards that can cause death, serious 

personal injury, or major property damage if ignored.
Warns about hazards that may cause death, serious 

personal injury, or major property damage if ignored.
Warns about hazards that may or can cause minor 

personal injury or property damage 

if ignored.

           NOTE

   

    Indicates special instructions not related to  

 

 

 

    hazards.

Carefully read and follow all safety instructions in this manual and on 

equipment. Keep safety labels in good condition; replace if missing or 

damaged.

READ AND FOLLOW 

ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

IMPORTANT NOTICE

Do not permit children to use this product.

ii

Содержание C Series

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS C SERIES INSTALLATION GUIDE BRONZE COMMERCIAL PUMP ...

Страница 2: ...s and pool products please contact CUSTOMER SERVICE TECHNICAL SUPPORT Customer Service and Technical Support USA 8 A M to 5 P M Eastern Pacific Times Phone 800 831 7133 Fax 800 284 4151 Web site Visit www pentaircommercial com to find more information about Pentair products Sanford North Carolina 8 A M to 5 P M ET Phone 919 566 8000 Fax 919 566 8920 Moorpark California 8 A M to 5 P M PT Phone 805 ...

Страница 3: ... WARNINGS AND ALL INSTRUCTIONS IN THE OWNER S MANUAL BEFORE USING THIS PUMP THESE WARNINGSAND THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAINANDAWAYFROMALLSUCTION OUTLETS THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOLOR SPAWHEN COVERSARE MISSING CRACKED OR BROKEN CAN RESULT IN BODY OR LIMB ENTRAPMENT HAIR ENTANGLE MENT BODY ENTRAPMENT...

Страница 4: ...son comes within the close proximity of the suction openings A person can be seriously injured by this high level of vacuum or may become trapped and drown It is absolutely critical that the suction plumbing be installed in accordance with the latest national and local codes for swimming pools The Virginia Graeme Baker VGB Pool and Spa SafetyAct creates new requirements for owners and operators of...

Страница 5: ...and impeller 15 are completely out of the volute 7 Avoid resting entire unit on seal flange and impeller 3 Remove Allen head cap screw 12 and washer 13 from center of impeller 15 Pull impeller from shaft Do not lose square key 21 4 Remove seal spring member 16 from shaft Avoid cutting rubber parts or scratching carbon face 5 Remove two hex head cap screws 19 from seal flange 17 Hold seal flange so...

Страница 6: ...sher C 71 Pump Model Motor P Ns Impeller P Ns 1PH 230V 60Hz 1PH 200V 60Hz 3PH 200V 60Hz 3PH 208 220 440V 60Hz 190 380V 50Hz 3PH 575V 60Hz 3PH 200V 60Hz 3PH 350 415V 50Hz 3PH 380 400V 60Hz CH CHK 50 071366 357205 357206 071364 357237 357206 072737 071368 073828 CH CHK 75 357204 357207 357208 071365 357247 357208 072739 071369 073829 CH CHK 100 357249 357209 071363 357238 357209 072740 071370 073830...

Страница 7: ...1 10m 15 40 85m 20 42 07m Pump Performance Curve CH CHK Series Pump CH CHK SERIES PUMP 60 CYCLE 3450 RPM TOTAL DYNAMIC HEAD IN FEET OF WATER 160 140 120 100 80 60 40 20 0 0 100 200 300 400 500 600 700 800 900 1000 FLOW RATE IN GPM CHK 200 20 HP CHK 150 15 HP CHK 100 CH 100 10 HP CHK 75 CH 75 7 5 HP CHK 50 CH 50 5 HP Pump Performance Curve CM CMK Series Pump CM CMK SERIES PUMP 60 CYCLE 3450 RPM TOT...

Страница 8: ...essly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of those third parties Because we are continuously improving our products and services Pentair reserves the right t...

Отзывы: