1.0 Mounting instructions

note

All AVID LP switchboxes are factory equipped with 
direct and NAMUR mounting.

1.1  Please refer to the figures 1 and 2 below 

to determine the type of mounting that is 
required.

 

Figure 1 indicates the conventional direct 
mount and figure 2 details the NAMUR 
option.

1.2  Operate the actuator to the fully closed 

position.

1.3 Direct mount

1.3a  Before mounting the AVID LP it will be 

necessary to remove the cover.

1.3b  To do this, loosen the 4 off M5 captive 

screws with either a 8 mm A/F spanner / 
socket drive or an appropriately sized flat 
blade screwdriver.

1.3c  Remove the cover assembly by lifting 

the cover vertically. Keep the cover safe 
taking care not to damage the cover seal 
detail.

© 2014 Pentair Ltd. All Rights Reserved.

Figure 1

Figure 2

Installation and operating instructions for AVID LP R2 with SPDT V3 Microswitches, 

V3 Inductive Proximity Sensors or T-Switches.

AViD

 LP R2

InstallatIon and operatIng InstructIons

www.pentair.com/valves

VcioM-02984-en 14/08

The following document details the installation, 
operation and maintenance instructions for the 
AVID LP R2 (low profile) giving 360° visual and 
electrical valve position.

1.4 nAMur Mount

note

Due to the mounting hole pattern of the AVID LP 
housing being 93.5 x 41.3 mm equal about the center 
of the shaft, a modified Namur bracket is required. 
The modification can either be 4 off M5 tapped holes 
or 4 off M5 clearance holes.

1.4a  Secure the appropriately sized modified 

Namur bracket to the actuator using 
the screws / washers supplied with the 
Namur kit finger tight only.

1.4b(1) For mounting brackets with 4 off M5 

tapped holes, mount the LP switchbox 
to the mounting bracket by engaging 
the Namur shaft drive into the actuator 
Namur pinion slot.

1.3d  Mount the AVID LP switchbox to the 

actuator by aligning the 11 x 16 mm shaft 
adaptor to the actuator pinion coupler.

1.3e  Ensure that the base of the AVID LP 

housing sits flush with the top of the 
actuator.

1.3f  Locate and tighten the 4 off M5 captive 

screws in the base of the housing with 
either a 8 mm A/F socket drive or an 
appropriately sized flat blade screwdriver.

1.3g  Tighten the screws to a torque value of 

18 to 22 Lb/Ins.

AVID coupler 11 x 16 mm

Actuator namur slot

Namur 

shaft drive

Bracket – customer supply

1.4b(2) Locate and tighten the 4 off M5 captive 

screws in the base of the housing with 
either a 8 mm A/F spanner / socket 
drive or an appropriately sized flat blade 
screwdriver.

1.4b(3) Tighten the screws to a torque value 

of 18 to 22 Lb/Ins.

1.4c(1)  For mounting brackets that have 4 off 

M5 clearance holes it will be necessary 
to replace the 4 off M5 captive 
LP housing mounting screws with 
M5 x 16 mm screws to be sealed with 
new sealing caps.

1.4c(2)  Tighten the screws to a torque value 

of 18 to 22 Lb/Ins.

Отзывы: