manualshive.com logo in svg
background image

3

5. If replacing capacitor, remove wires from capacitor. Remove

capacitor.

6. Slide a small screwdriver down beside shaft and pry lip seal

out. Discard lip seal. Be careful not to scratch shaft.

7. Remove retaining ring and washer from motor shaft and

slide rotating half of seal off of shaft.

8. Cradle motor assembly so that it stands vertically with motor

shaft extending out of the bottom.

9. Remove  motor cover from seal plate. Remove through bolts

from motor assembly. Remove motor and shaft from seal
plate.

10. With screwdriver, gently tap seat ring out of seal plate; 

thoroughly clean seat cavity.

Re-assembly

NOTICE:

Make sure that seal faces are clean and undamaged.

1. Apply Permatex #2 or equivalent sparingly to outside edge

of seal body. Press new seal body into cavity in seal plate.

2. Reverse steps 7 through 9 above to reassemble motor and

shaft.

NOTICE:

Do not overtighten through bolts!

3. Slide new rotating member of seal onto shaft.

NOTICE:

Coat rubber bellows with soap or oil to aid in

installing seal on shaft.

NOTICE:

Do not nick or scratch carbon seal face when

passing it over shaft shoulder. Seal faces must be clean and
undamaged or seal may leak.

4. Reinstall snap ring on shaft.
5. Reassemble impeller, washer, and impeller screw .
6. Install new capacitor (single phase). See picture below for

electrical connections to capacitor.

7. Fill motor with clean dielectric oil (Part No. U197-8A). To

allow room for expansion, oil level with cold motor should
be about 1/4” above top of motor assembly.

8. Inspect O-Ring gasket; replace if damaged.  If it is not

nicked or scratch, clean and reinstall.

9. Reinstall capacitor cover, adjust power cord in connector

and retighten connector.

REPAIR PARTS

Rope Handle Ring

U97-102SS

Cord Assembly

Single Phase: PW117-232A-TSE

Single Phase Auto: PW117-240-TSE

Three Phase: PW117-235-TSE

Oil Fill Plug  

U78-57DV

Dielectric Oil

  U197-8A

Capacitor (Single Phase Only)

U18-1566

5/16-18 Hex Capscrew

U30-62SS

Motor Through Bolt

U30-942

Capacitor Cover

PW3-16A

Motor Cover

PW3-32A

Impeller

1 HP: PW5-7B

1 1/2 HP: PW5-7A

2 HP: PW5-7

Seal Plate O-Ring

U9-351

Capacitor Cover O-Ring

U9-339

Motor Assembly

Single Phase: PW218-117

Three Phase: PW218-118

Seal Plate

PW3-34

Shaft Seal

U9-394SS

Woodruff Key

U65-2SS

1/4-20 Hex Capscrew  

U30-52SS

5/16-18 Hex Capscrew

  

U30-65SS

1/4 Flat Washer  

PW43-4SS

Retaining Washer  

PW43-5SS

Retaining Ring        

U9-353SS

Volute

PW1-5W

1/4-20 Socket Hd. Screw

U30-475SS

1307C 0597

Lip-Oil Seal

U9-417

Содержание 900S Series

Страница 1: ...e Can shock burn or cause death During operation the pump is in water To avoid fatal shocks proceed as follows if pump needs servicing 7A Ground pump according to all applicable codes and ordinances 7B Disconnect power to outlet box or circuit breakers before servicing 7C To reduce risk of electric shock take care when changing fuses or resetting circuit breakers Do not stand in water when working...

Страница 2: ...0 1 25 15 1 11 2 2 220 50 3 20 12 1 11 2 2 380 50 3 15 8 Operation and Installation NOTICE Do not allow pump to run in a dry sump It will void the warranty and may damage the pump In 1 phase units an automatic overload protector in the motor will protect motor from burning out due to overheating overload ing When motor cools down protector will automatically reset and start motor If overload trips...

Страница 3: ...be clean and undamaged or seal may leak 4 Reinstall snap ring on shaft 5 Reassemble impeller washer and impeller screw 6 Install new capacitor single phase See picture below for electrical connections to capacitor 7 Fill motor with clean dielectric oil Part No U197 8A To allow room for expansion oil level with cold motor should be about 1 4 above top of motor assembly 8 Inspect O Ring gasket repla...

Страница 4: ...utes to allow motor to cool then reconnect to power source Check for cause of overheating overloading B Pump fails to empty sump 1 Be sure all valves in discharge valve are fully open 2 Clean out discharge pipe and check valve 3 Check for blockage in pump inlet or impeller 4 Pump not sized properly A higher capacity pump may be required C Pump will not shut off 1 Check switch or controller automat...

Отзывы: